background image

Содержание 86005760

Страница 1: ...AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation and keep it for future reference The mixer shower installation...

Страница 2: ...11 OPERATING THE SHOWER 12 COMMISSIONING 13 ANTI SCALD PROTECTION 13 ADJUSTING THE MAXIMUM TEMPERATURE SETTING 14 PRODUCT FLOW RATES 15 MAINTENANCE 16 CLEANING THE FILTERS 16 MODEL NAMES AND PRODUCT...

Страница 3: ...Thermostatic Mixer Shower 1 Valve Handle Variations 7 1 2 3 4 5 6 Fig 1 Main components MAIN COMPONENTS 1 Mixer shower body 5 Inlet nut and olive x2 2 Blanking plug 6 Wall trim x2 3 Outlet adaptor 7 H...

Страница 4: ...Mini Exposed Sequential Thermostatic Mixer Shower 2 60mm 135mm 36mm G1 2 102mm 150mm 200mm DIMENSIONS All dimensions regarding the product and installation are approximate Fig 2...

Страница 5: ...nts and will minimise the effects of scale in hard water areas Valves operating outside these conditions of use cannot be guaranteed to operate as Type 2 valves Pressure Reducing Valve On sites where...

Страница 6: ...ystem of debris and check for leaks before connecting to the mixer Commercial Applications For commercial applications in line filters are recommended Hard Water Areas a If it is intended to operate t...

Страница 7: ...a pump to boost pressures as shown please refer to the pump installation guide to establish the minimum head requirements for automatic operation of the pump Hot water cylinder Cold supply Hot supply...

Страница 8: ...r For systems with no cold water take off after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when the mains pressure is over 5 bar The drop...

Страница 9: ...exceed 5 bar running An expansion vessel MUST be fitted and regularly maintained to ensure the unit is not damaged by excess pressures This may already be installed externally or internally within the...

Страница 10: ...or fixed shower head can be positioned above or to either side of the shower fig 8 The valve must be installed in a position that allows for easy access for future maintenance and commissioning FITTIN...

Страница 11: ...lbows have O ring seals fig 12 to the body and do not require PTFE tape or other means of sealing Fit the trim onto the inlet water pipes followed by the nut and olive Connect the hot water supply to...

Страница 12: ...nnection unscrew the outlet adaptor Place the flow regulator into the rigid pipe connection end please note the flow regulator is only designed to work in one direction fig 14 The flow regulator for 1...

Страница 13: ...e temperature control knob as shown in fig 15 Ensure the maximum temperature stop pin is as close to the flat edge of the maximum temperature stop as possible Secure the knob in place with the retaini...

Страница 14: ...he shower turn the on off temperature control anti clockwise fig 16 To adjust the showering temperature rotate the temperature control clockwise for cooler and anti clockwise for hotter CAUTION Expose...

Страница 15: ...de a maximum temperature of 35 C 40 C and should be checked on site to guarantee user safety The following is recommended for domestic installations but must be carried out for commercial installation...

Страница 16: ...h fill but see notes below 41 C for showers 41 C for washbasins 38 C for bidets The mixed water temperatures must never exceed 46 C at terminal fitting The British Burns Association recommends 37 to 3...

Страница 17: ...nce only Conditions for test Inlet temperatures comply with EN1111 requirements Outlet Temperatures 38 C Flow Control open Open outlet No hose or shower head connected Flow Rate l m 6 2 7 8 9 5 10 8 1...

Страница 18: ...ves are fully open Check the internal surface for scaling If the body requires descaling then it should be removed from the pipework to carry out this work all rubber parts must be removed before desc...

Страница 19: ...Mini Exposed Sequential Thermostatic Mixer Shower 17 MODEL NAME PRODUCT CODE ASANA SFXASATHSM DENE UNDETHEXSQM MOYA HMMOYTHSMMNFH PREMA TOLPRETHSM...

Страница 20: ...and from the mains supply 2 Water too cold 2 1 Temperature control incorrectly commissioned 2 1 1 Refer to the Commissioning section 2 2 Not enough hot water flowing through shower 2 2 1 Reposition th...

Страница 21: ...head blocked 4 4 1 Clean the shower head 4 5 System not capable of supplying multiple outlets at the same time 4 5 1 Make sure stop or service valve is fully open 4 5 2 Check if there is sufficient wa...

Страница 22: ......

Страница 23: ......

Страница 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...

Отзывы: