For the installation, you need one:
MSD Platinum 17 RA
Procedures:
1
)
Please put the fixture on a smooth desk,
2
)
First, take off the upper and down cover from the lamp head, release the three screws that
the letter A pointed to, then it can take down the plate of lamp-socket.
3
)
Before taking off the lamp, please release the two red wires which connect to the lamp.
Then take off the plate of the lamp carefully, please press the lamp and cover for
lamp-socket.
Make sure remove the lamp from left to right until the lamp is took off. Attention, wrap the
lamp with soft cloth which go with the lamp to avoid your finger touching the glass of lamp
directly.
4
)
Replace lamp and make it stable. Please be noted that there's only one installation direction
for the lamp. Make sure the replaced lamp has the same installation direction with the old
one.Once again, make sure it’s stable.
5
)
Put on the plate of lamp socket and tighten screw.
6
)
Please reset the lamp life-time. Otherwise it is likely to trigger the protecting firmware of
system to make the replaced lamp close itself automatically.
Please remember the lamp is not a hot-restrike type, you must wait for approximately 10
minutes after having turned off the lamp before you can turn it back on again.
Do not operate this device with open cover