Installation
SeaKing Profiling Sonar
0374-SOM-00002, Issue: 04
14
© Tritech International Ltd.
Note
If using the dual Profilers with a
Tritech International Ltd
SeaHub
or SCUv5 it is possible to link pin 5 at the surface and use standard
cables instead. Refer to the SeaHub or SCU manual for further
details.
Note
Wire colours shown correspond to standard
Tritech International
Ltd
6-pin connector and cable.
3.3.6. Using two Profilers with RS232 or RS485
When using RS232 or RS485 it is still possible to use two Profilers, but each
must have their own communications channel to the topside controller (i.e. a
dedicated COM Port for each unit).
Seanet Pro must then be set to use the Profilers in the
Free Run
mode. See
the section called “Setup” for more details.