12
INSTALLATION
Selection of installation location
Put the mobile air conditioner in a flat location where the air outlets cannot be blocked, place the unit no less
than 50cm(20 inch) away from a wall or other obstacle.
Mounting method of the air exhaust duct
1) Fix the square end of the exhaust dust to the exhaust terminal of the unit
2) Put the other end (discharge) to the nearest window. Caution: The length of the air exhaust
should be between 600mm-1800mm (23.6 inch-70.8 inch). Use the Minimum length when
operating. When mounting, it is suggested to try to keep the air exhaust horizontal, not permit any
expansion or connect the other end (discharge). Otherwise, it will cause malfunction.
CAUTION
hot air terminal
window
air duct attachment for
heat exhaust
air exhaust opening