hot-swappable whole UPS replacement with no interruption to connected equipment
L6-30P input plug; two L6-30R and two L6-20R outlets
Included rail kit supports 4U 19 inch rackmount installation in 4 post racks
Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (1 required for SU6000RT4UHV)
Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UHV)
Maximum installed rack depth of only 20.7 in. / 52.6cm
Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode
Corrects brownouts to 156V at full load (100V at 50% load or less)
Corrects overvoltages to 290V at full load (300V at 90% load or less)
Supports 50/60Hz operation for worldwide frequency compatibility
Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with
enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS
types
High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs
Network-grade AC surge and noise suppression
Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional
SNMP card slot interfaces
UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part #
RELAYIOCARD)
Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces
Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification
Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires
removal of USB interface module)
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA
(Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250
SNMP-enabled UPS, PDU and other networking devices
Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a
variety of control options to support advanced UPS settings and configurations
LED/LCD display panel rotates for viewing in rackmount or tower configurations
Supports Emergency Power Off (EPO) via built-in interface
Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries
are expired and require replacement
BP192V12-3U external battery packs are field replaceable and hot swappable
Some external battery configurations require the use of Tripp Lite's
External Battery Configuration Software
(see manual)
Frequency conversion mode enables conversion of 60Hz to 50Hz or 60Hz to 50Hz (no de-rating)
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
6000
Output kVA capacity
(kVA)
6.0
Output Watt Capacity
(watts)
5400
Output kW capacity
5.4
Output power factor
0.9
Output Capacity
Details
Output capacity de-rates to 4992 watts when used at 208V nominal
Crest Factor
3:1
Nominal Output
Voltage(s) Supported
200V; 208V; 220V; 230V; 240V