Model #: SU6000RT4UHV
SmartOnline 6kVA On-Line Double-Conversion UPS, 4U Rack/Tower, 200-240V NEMA outlets
Highlights
Completely user hot-swappable—no service call or technician needed
Protects rackmount servers, telecom systems and other networking
equipment in high-voltage environments with true on-line operation, pure sine
wave output and zero transfer time
4 AC outlets (2 L6-20R; 2 L6-30R) with 200/208/220/230/240V 50/60Hz output
6kVA/5400W capacity in 4U form factor with power module and independent,
detachable PDU
Hot-swappable power and battery modules
8.5-minute half-load runtime, 2-minute full-load; expandable runtime with
external battery packs
Front panel LEDs with detailed LCD monitoring and control screen
USB, RS232 and SNMP communication ports with included PowerAlert
software for complete network power management and control
$250,000 Ultimate Lifetime Insurance; 2-year warranty
Description
Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no
downtime, the SU6000RT4UHV provides the highest level of protection available for mission-critical equipment from power outages, voltage
fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating
connected components from all power problems in high-voltage environments. The SU6000RT4UHV has a 6kVA/5400W capacity and 4 AC outlets
(2 L6-20R; 2 L6-30R).
With its detachable PDU, the SU6000RT4UHV is easily hot-swappable by a user of any skill set—no need for lengthy and expensive service calls,
and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power
and battery modules, allowing them to be removed while keeping your application in operation.
UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly
system shutdown in case of a prolonged blackout. The SU6000RT4UHV‘s runtime can be expanded with optional external battery packs.
The SU6000RT4UHV features a highly efficient (96%) economy mode setting that can significantly reduce a facility's energy costs by minimizing
heat output, reducing cooling requirements and consuming less electricity.
An LCD display with LED indicators enables IT personnel to monitor operating modes and conditions. The LCD/LED panel rotates for viewing in
horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions.
The SU6000RT4UHV features a USB port and a DB9 port that, when used with Tripp Lite's included PowerAlert software, provide comprehensive
network power monitoring and control. An optional SNMPWEBCARD accessory can enable the UPS to operate as an IP managed device.
The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or
in a tower configuration with the 2-9USTAND accessory.
The SU6000RT4UHV comes with $250,000 Ultimate Lifetime Insurance coverage for connected equipment and a 2-year warranty.
Features
Tripp Lite SU6000RT4UHV 6000VA / 6kVA / 5400 watt online, double-conversion UPS system in a single 4U rack/tower compatible housing
(at 208V nominal, output is limited to 4992 watts)
Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions
and line noise
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Detachable back panel PDU contains input line cord connection and output receptacles, plus manual bypass switch to support
hot-swappable whole UPS replacement with no interruption to connected equipment