background image

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and
execute scrolling LCD functions

SURGE / NOISE SUPPRESSION

UPS AC
suppression joule
rating

480

UPS AC
suppression
response time

Instantaneous

EMI / RFI AC noise
suppression

Yes

PHYSICAL

Installation form
factors supported
with included
accessories

4 post 19 inch rackmount (mounting rail kit included); Tower

Included mounting
accessory
description

2 sets of adjustable 4 post rack rails included

Installation form
factors supported
with optional
accessories

2 post rackmount (2POSTRMKITWM)

Optional mounting
accessory notes

2 sets of 

2POSTRMKITWM

 required for 2 post rackmount installation of separate power module and battery pack

Primary form factor

Rackmount

UPS / Power
Module dimensions
in primary form
factor (height x
width x depth /
inches)

5.2 x 17.5 x 26

UPS / Power
Module dimensions
in primary form
factor (height x
width x depth / cm)

13.3 x 44.4 x 66

Installed whole
system maximum
rack depth (inches)

26

Installed whole
system maximum
rack depth (cm)

66

Installed whole
system total rack
space height (rack
spaces)

6U

Secondary form
factor

Tower (requires 

2-9USTAND

)

UPS / Power
Module weight (lbs)

43.8

UPS / Power
Module weight (kg)

19.9

Содержание SmartOnline SU6000RT3UHV

Страница 1: ...n DB9 port offers both enhanced RS 232 data and basic contact closure monitoring ability Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface LED display repo...

Страница 2: ...kVA capacity kVA 6 Output Watt Capacity watts 4200 Output kW capacity 4 2 Output power factor 0 7 Crest Factor 3 1 Nominal Output Voltage s Supported 200V 208V 220V 230V 240V Nominal Voltage details...

Страница 3: ...C 1PH External battery pack compatibility BP240V10RT3U BP240V557C 1PH BP240V787C 1PH BP240V1037C 1PH BP240V1407C 1PH DC system voltage VDC 240 Battery recharge rate included batteries Less than 6 hour...

Страница 4: ...tion form factors supported with optional accessories 2 post rackmount 2POSTRMKITWM Optional mounting accessory notes 2 sets of 2POSTRMKITWM required for 2 post rackmount installation of separate powe...

Страница 5: ...perature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC mode BTU hr full load 1412 3 AC economy mode BTU hr full load 911 5 Battery mode BTU hr...

Страница 6: ...arranty For SU6000RT3UHV only 1 Extended Warranties WEXT5 SU6000HV 5 Year Extended Warranty For SU6000RT3UHV only 1 External Battery Packs BP240V1037C 1PH External battery pack for use with select Tri...

Страница 7: ...at www tripplite com en products model cfm txtModelID 1972 Copyright 2012 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of con...

Отзывы: