background image

Output Watt
Capacity (watts)

1350

Output kW
capacity

1.35

Output power
factor

0.9

Output Capacity
Details

ON LINE MODE: Maximum output capacity ratings are reduced for some nominal voltage settings (127/120V 1350
watts, 115V 1215 watts, 110V 1148 watts and 100V 1080 watts). FREQUENCY REGULATION / CONVERSION
MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 945 watts, 115V 851
watts, 110V 804 watts, 100V 756 watts).

Crest Factor

3:1

Nominal Output
Voltage(s)
Supported

100V; 110V; 120V; 127V

Nominal Voltage
details

120V default

Frequency
compatibility

50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion

Frequency
compatibility
details

ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output
matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds
+/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY
REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40
to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output
is regulated to +/-0.05Hz of selected nominal.

Output voltage
regulation (line
mode)

+/- 2%

Output voltage
regulation
(Economy line
mode)

+/- 10%

Output voltage
regulation (Battery
mode)

+/- 3%

Built-in UPS
output receptacles

6 5-15R outlet(s)

Built-in
controllable
switched load
banks

Two switchable three-outlet load banks

Output AC
waveform (AC
mode)

Pure Sine wave

Output AC
waveform (battery
mode)

Pure Sine wave

INPUT

Rated input
current (at
maximum load)

12A

Nominal Input
Voltage(s)
Supported

100V AC; 110V AC; 120V AC; 127V AC

Содержание SmartOnline SU1500XLCD

Страница 1: ...meters and line power status Included PowerAlert power management software supports an unlimited number of network UPS systems The SU1500XLCD also accepts an optional SNMPWEBCARD accessory that enables the UPS to operate as a managed device on the network It comes backed by a 2 year warranty and 250 000 of Ultimate Lifetime Insurance Package Includes SU1500XLCD SmartOnline Tower UPS System PowerAl...

Страница 2: ... provides surge protection for a standard phone or network connection cable not included EMI RFI Line Noise Filtering Various electrical and radio sources can cause disruptive interference on the AC line This line noise is a common cause of incremental hardware damage data corruption and audio video performance problems The SU1500XLCD incorporates technology that filters out disruptive line noise ...

Страница 3: ...ut frequency on startup Output matches input frequency when 5Hz of nominal Output is regulated to 0 05Hz when input frequency exceeds 5Hz of nominal UPS switches to battery mode when input frequency is below 40Hz or above 70Hz FREQUENCY REGULATION CONVERSION MODE Output is regulated to 0 05Hz of selected output frequency when input is 40 to 70Hz UPS switches to battery mode when input frequency is...

Страница 4: ...teries Less than 3 hours from 10 to 90 Replacement battery cartridge internal UPS battery replacement RBC48 SUTWR Battery Access Battery access door Battery replacement description Hot swappable user replaceable batteries VOLTAGE REGULATION Voltage regulation description Online double conversion power conditioning Overvoltage correction 2 output voltage regulation during overvoltages to 150 Underv...

Страница 5: ...ise suppression Yes PHYSICAL Installation form factors supported with included accessories Tower Primary form factor Tower UPS Power Module dimensions in primary form factor height x width x depth inches 10 2 x 9 x 19 5 UPS Power Module dimensions in primary form factor height x width x depth cm 25 9 x 22 9 x 49 5 UPS Power Module weight lbs 52 3 UPS Power Module weight kg 23 7 UPS Shipping dimens...

Страница 6: ...ommunications cable USB and DB9 cabling included WatchDog compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER Transfer time Zero transfer time 0 ms in online double conversion and frequency regulation conversion modes Low voltage transfer to battery power setpoint 55V 33 load 70V 70 load 100V 100 load High voltage transfer to...

Страница 7: ...uires ENVIROSENSE 1 PDUB15 Single Phase Hot Swap PDU 15A 120V 2U Horizontal Rackmount 8 NEMA 5 15R outlets set of 2 NEMA 5 15P input plugs 1 PDUMH15AT Single Phase Auto Transfer Switch Metered PDU 15A 120V 1U Horizontal Rackmount 8 NEMA 5 15R outlets 2 NEMA 5 15P inputs 1 PDUMNV15 Single Phase Monitored PDU 15A 120V 0U Vertical Rackmount 16 NEMA 5 15R outlets NEMA 5 15P input plug 1 PDUMV15NET Sin...

Отзывы: