Output voltage
regulation (Economy
line mode)

+/- 10%

Output voltage
regulation (Battery
mode)

+/- 2%

Built-in UPS output
receptacles

Hardwire

Output AC waveform
(AC mode)

Pure Sine wave

Output AC waveform
(battery mode)

Pure Sine wave

INPUT

Rated input current
(at maximum load)

56.1A (200V), 54A (208V), 51A (220V), 48.8A (230V), 46.8A (240V)

Nominal Input
Voltage(s) Supported

200V AC; 208V AC; 220V AC; 230V AC; 240V AC

UPS input
connection type

Hardwire

UPS input
connection
description

3 wire single phase input (L1, L2, G)

Recommended
Electrical Service

60A

BATTERY

Full load runtime
(minutes)

4.3 min. (9000w)

Half load runtime
(minutes)

12.5 min. (4500w)

Expandable battery
runtime

Supports extended runtime with optional external battery packs

External battery
pack compatibility

BP240V10RT3U

BP240V557C-1PH

BP240V787C-1PH

BP240V1037C-1PH

BP240V1407C-1PH

DC system voltage
(VDC)

240

Battery recharge
rate (included
batteries)

Less than 8 hours from 10% to 90%

Battery replacement
description

Hot-swappable, user replaceable external battery packs

VOLTAGE REGULATION

Voltage regulation
description

2% output voltage regulation in standard online, double-conversion mode

Overvoltage
correction

Corrects overvoltages up to 300V

Undervoltage
correction

Corrects undervoltages as low as 100V

LEDS ALARMS & SWITCHES

Содержание SmartOnline SU10KRT3UHV

Страница 1: ...rial locations Package Includes SU10000RT3UPM 3U UPS power module BP240V10RT3U external battery pack SUPDMB710HW Detachable PDU with manual bypass switch Four post compatible rack rail kit 2 sets Towe...

Страница 2: ...er Off EPO via built in interface Included rail kit supports 6U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks Front panel LEDs and...

Страница 3: ...Y Full load runtime minutes 4 3 min 9000w Half load runtime minutes 12 5 min 4500w Expandable battery runtime Supports extended runtime with optional external battery packs External battery pack compa...

Страница 4: ...swap UPS power module replacement SURGE NOISE SUPPRESSION UPS AC suppression response time Instantaneous EMI RFI AC noise suppression Yes PHYSICAL Installation form factors supported with included ac...

Страница 5: ...lbs 327 6 Shipping weight kg 148 7 UPS housing material Steel Cooling method Fan ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius Storage Temperature Ran...

Страница 6: ...ge varies beyond 10 with less than 1 millisecond transfer time between modes High availability UPS features Automatic inverter bypass Manual bypass switch Detachable hot swap PDU Hot swappable UPS pow...

Страница 7: ...eb or Telnet 1 SNMP Accessories SRSWITCH Magnetic Door Switch Kit for front and rear doors requires ENVIROSENSE 1 UPS Accessories MODBUSCARD For remote monitoring and control via MODBUS protocol 1 UPS...

Отзывы: