background image

 

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail: 

[email protected]

Model #: SU10KRT3UHV

SmartOnline 10kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 200-240V Hardwire output

 

Highlights

10kVA / 10,000VA / 9000W on-line double-conversion UPS; 0.9 power factor

200/208/220/230/240V 50/60Hz output; Economy mode option

6U Rack / Tower compatible; Hot-swappable power and battery modules

USB, RS232 & EPO ports; support for SNMP/WEB and contact-closure card

options

Front panel LEDs with detailed LCD monitoring and control screen

Expandable runtime with optional external battery packs

Hardwire input (3 wire); Hardwire output

Description

 Tripp Lite SU10KRT3UHV 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete power protection for critical
network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking
applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included
detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected
equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking
applications in data centers, computer rooms, network closets and rugged industrial locations. 

Package Includes

SU10000RT3UPM 3U UPS power module

BP240V10RT3U external battery pack

SUPDMB710HW Detachable PDU with manual bypass switch

Four post compatible rack rail kit (2 sets)

Tower stands for upright tower configuration

PowerAlert software, complete data cabling and user manual

Features

Tripp Lite SU10KRT3UHV 10kVA / 10,000VA / 9000 watt on-line, double-conversion UPS system in 6U total rack/tower configuration (3U

UPS power module and 3U external battery pack)

Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to

connected networking equipment

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Hardwire input and output connections

Maximum installed rack depth of only 32.5 in. / 82.6cm 

Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions

and line noise

Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with

enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS

types

Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and

overvoltages as high as 300V

Supports 50/60Hz operation for worldwide frequency compatibility

Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH;

BP240V1407C-1PH external battery packs

Содержание SmartOnline SU10KRT3UHV

Страница 1: ...rial locations Package Includes SU10000RT3UPM 3U UPS power module BP240V10RT3U external battery pack SUPDMB710HW Detachable PDU with manual bypass switch Four post compatible rack rail kit 2 sets Towe...

Страница 2: ...er Off EPO via built in interface Included rail kit supports 6U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks Front panel LEDs and...

Страница 3: ...Y Full load runtime minutes 4 3 min 9000w Half load runtime minutes 12 5 min 4500w Expandable battery runtime Supports extended runtime with optional external battery packs External battery pack compa...

Страница 4: ...swap UPS power module replacement SURGE NOISE SUPPRESSION UPS AC suppression response time Instantaneous EMI RFI AC noise suppression Yes PHYSICAL Installation form factors supported with included ac...

Страница 5: ...lbs 327 6 Shipping weight kg 148 7 UPS housing material Steel Cooling method Fan ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius Storage Temperature Ran...

Страница 6: ...ge varies beyond 10 with less than 1 millisecond transfer time between modes High availability UPS features Automatic inverter bypass Manual bypass switch Detachable hot swap PDU Hot swappable UPS pow...

Страница 7: ...eb or Telnet 1 SNMP Accessories SRSWITCH Magnetic Door Switch Kit for front and rear doors requires ENVIROSENSE 1 UPS Accessories MODBUSCARD For remote monitoring and control via MODBUS protocol 1 UPS...

Отзывы: