background image

UPS / Power Module
weight (kg)

13.2

UPS Shipping
dimensions (height x
width x depth / inches)

9.5 x 20 x 24

UPS Shipping
dimensions (height x
width x depth / cm)

24.1 x 50.8 x 61

Shipping weight (lbs)

41

Shipping weight (kg)

18.6

UPS housing material

Steel

Cooling method

Fan

ENVIRONMENTAL

Operating
Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature
Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC mode BTU / hr.
(full load)

406.4

AC economy mode
BTU / hr. (full load)

173.6

Battery mode BTU /
hr. (full load)

442.8

AC economy mode
efficiency rating
(100% load)

94%

COMMUNICATIONS

Communications
interface

USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface

Network monitoring
port description

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure
communications

PowerAlert software

Included

Communications
cable

USB and DB9 cabling included

WatchDog
compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER

Transfer time

No transfer time (0 ms.) in online, double-conversion mode

Low voltage transfer
to battery power
(setpoint)

80V (100% load), 65V ( 

High voltage transfer
to battery power
(setpoint)

150

SPECIAL FEATURES

Содержание SmartOnline SU1000RTXL2Ua

Страница 1: ...peration Network management interfaces support simultaneous communications via USB port DB9 serial port and SNMPWEBCARD slot Built in DB9 port offers both enhanced RS 232 enabled monitoring data plus...

Страница 2: ...built in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected s...

Страница 3: ...ectrical Service 15A 120V BATTERY Full load runtime minutes 4 5 min 800w Half load runtime minutes 14 min 400w Expandable battery runtime Extended runtime supported via optional external battery packs...

Страница 4: ...ncel switch Switches 2 switches control off on power status and alarm cancel self test operation SURGE NOISE SUPPRESSION UPS AC suppression joule rating 510 UPS AC suppression response time Instantane...

Страница 5: ...ll load 442 8 AC economy mode efficiency rating 100 load 94 COMMUNICATIONS Communications interface USB HID enabled DB9 Serial Contact closure EPO emergency power off Slot for SNMP Web interface Netwo...

Страница 6: ...rce Power Distribution Unit PDU with Manual Transfer Switch enables Hot swappable UPS Replacement in Critical Network Applications 1 Power Distribution PDUMH15AT Metered PDU with ATS Power Distributio...

Страница 7: ...r s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModelID 2948 Copyright 2012 Tripp Lite All rights reserved All trademarks are the...

Отзывы: