background image

Output voltage
regulation (Battery
mode)

+/- 2%

Built-in UPS output
receptacles

6 5-15R outlet(s)

Built-in controllable
switched load banks

Two switchable single-outlet 5-15R load banks

Output AC waveform
(AC mode)

Sine wave

Output AC waveform
(battery mode)

Pure Sine wave

INPUT

Rated input current
(at maximum load)

8.6A

Nominal Input
Voltage(s) Supported

100V AC; 110V AC; 120V AC

UPS input connection
type

5-15P

Input circuit breaker

15A

UPS Input cord
length (ft.)

10

UPS Input cord
length (m)

3

Recommended
Electrical Service

15A 120V

BATTERY

Full load runtime
(minutes)

4.5 min. (800w)

Half load runtime
(minutes)

14 min. (400w)

Expandable battery
runtime

Extended runtime supported via optional external battery packs

External battery pack
compatibility

BP24V15RT2U

 (limit 1); 

BP24V28-2U

 (limit 1); 

BP24V70-3U

 (multi-pack compatible)

DC system voltage
(VDC)

24

Battery recharge rate
(included batteries)

Less than 6 hours from 10% to 80%

Replacement battery
cartridge (internal
UPS battery
replacement)

RBC92-2U

Battery Access

Front panel battery access door

Battery replacement
description

Hot-swappable, user replaceable batteries

VOLTAGE REGULATION

Voltage regulation
description

Online, double-conversion power conditioning

Содержание SmartOnline SU1000RTXL2Ua

Страница 1: ...peration Network management interfaces support simultaneous communications via USB port DB9 serial port and SNMPWEBCARD slot Built in DB9 port offers both enhanced RS 232 enabled monitoring data plus...

Страница 2: ...built in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected s...

Страница 3: ...ectrical Service 15A 120V BATTERY Full load runtime minutes 4 5 min 800w Half load runtime minutes 14 min 400w Expandable battery runtime Extended runtime supported via optional external battery packs...

Страница 4: ...ncel switch Switches 2 switches control off on power status and alarm cancel self test operation SURGE NOISE SUPPRESSION UPS AC suppression joule rating 510 UPS AC suppression response time Instantane...

Страница 5: ...ll load 442 8 AC economy mode efficiency rating 100 load 94 COMMUNICATIONS Communications interface USB HID enabled DB9 Serial Contact closure EPO emergency power off Slot for SNMP Web interface Netwo...

Страница 6: ...rce Power Distribution Unit PDU with Manual Transfer Switch enables Hot swappable UPS Replacement in Critical Network Applications 1 Power Distribution PDUMH15AT Metered PDU with ATS Power Distributio...

Страница 7: ...r s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModelID 2948 Copyright 2012 Tripp Lite All rights reserved All trademarks are the...

Отзывы: