In addition to the contact closure monitoring of on battery, low battery and power restored messaging, built-in RS-232 interface supports
messaging of UPS and line power status, including AC line voltage, DC battery voltage and remaining battery capacity
Supports activate self-test and UPS output power control for delayed or immediate reboot of connected equipment
Diagnostic LEDs (indicate 17 performance conditions)
UL (USA), cUL (Canada), NOM (Mexico), FCC Class A (Emissions)
$250,000
Ultimate Lifetime Insurance
(USA & Canada Only)
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
3000
Output kVA capacity
(kVA)
3
Output Watt Capacity
(watts)
2400
Output kW capacity
2.4
Output power factor
0.8
Nominal Output
Voltage(s) Supported
120V
Frequency compatibility
60 Hz
Output voltage
regulation (line mode)
-13% / +5%
Output voltage
regulation (Battery
mode)
+/- 5%
Built-in UPS output
receptacles
4 5-15R outlet(s); 4 5-15/20R outlet(s)
Built-in controllable
switched load banks
Three switchable single-outlet 5-15R load banks
Output circuit breaker
15A branch rated (x2) - each breaker protects 4 outlets
Basic PDU options
PDU1220
(1U / 13 5-15/20R outlets);
PDUNV
(1U / 2 C19, 12 C13 outlets);
PDUV20
(0U / 12 5-15/20R outlets);
PDU40TDUAL
(0U / 40 5-15/20R outlets)
Metered PDU options
PDUMH20
(1U / 13 5-15/20R outlets);
PDUMH20
AT (1U / 16 5-15/20R outlets)*;
PDUMV20
(0U / 16 5-15/20R
outlets);
PDUMV40
(0U / 32 5-15/20R outlets)
Switched PDU options
PDUMH20ATNET
(1U / 16 5-15/20R outlets)*;
PDUMV20NET
(0U / 24 5-15/20R outlets)
External PDU
redundancy options
*Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS
models only
Output AC waveform
(AC mode)
Sine wave
Output AC waveform
(battery mode)
PWM sine wave
INPUT
Rated input current (at
maximum load)
22A
Nominal Input
Voltage(s) Supported
120V AC