background image

4

Operation

Switch Modes

Switch between the following operating modes as appropriate to your 

situation:

“ON”:

 Switch to this setting to provide connected 

equipment with AC power.

“OFF”: 

Switch to this setting to shut down the Inverter 

completely, preventing it from drawing power from the 

batteries. Use this switch to automatically reset the unit 
if it shuts down due to low battery or overload. Use an 
optional remote control module (Tripp Lite model 
APSRM4, sold separately or included with PV3000HF 
models) to reset unit due to overload only.

“REMOTE”: 

Switch to this setting to remotely monitor 

and control the Inverter with the use of an optional 

remote module. See remote module’s owner’s manual 

for operating instructions.

Indicator Lights

Your Inverter is equipped with a simple, intuitive, user-friendly set of 
indicator lights. These easily-remembered “traffic light” signals will allow 

you, shortly after first use, to tell at a glance the charge condition of your 

batteries, as well as ascertain approximate equipment load level.

“BATTERY” Indicator Lights:

 These three lights will illuminate in 

several sequences to show the approximate charge level of your connected 

battery:

Approximate Battery Charge Level†

Indicator Illuminated 

Battery Capacity

1

 

Green 

91%–Full

2

 

Green & Yellow 

81%–90%

3

 

Yellow 

61%–80%

4

 

Yellow & Red 

41%–60%

5

 

Red 

21%–40%

6

 

Flashing Red (slowly)* 

1%–20% 

7

 

Flashing Red (quickly)**  0% (Inverter has shutdown)

“LOAD” Indicator Lights:

 These three lights will illuminate in several 

sequences to show the approximate equipment load level on the Inverter’s 

AC receptacles.

Approximate Equipment Load Level

Indicator Illuminated 

Load Level

1

 

Green 

0%-50%

2

 

Green & Yellow 

51%-75%

3

 

Yellow 

76%-90%

4

 

Red 

> 90%

5

 

Flashing Red (quickly)**  OVERLOAD (Inverter has shutdown)

 Charge levels listed are approximate. Actual conditions vary depending on battery condition 

and load. * Approximately ½ second on, ½ second off. ** Approximately ¼ second on, ¼ second 
off. See “Resetting Your Inverter to Restore AC Power” to reset after Inverter shut down.

Resetting Your Inverter to Restore AC Power

Your Inverter may cease supplying AC power in order to protect itself 

from overload or to protect your electrical system. To restore normal 
functioning:

Low Battery Shutdown Reset:

 Set operating mode switch to “OFF” and 

run vehicle engine to recharge battery. When battery is adequately 

charged, switch operating mode switch back to either “REMOTE” or 
“ON.”

Overload Shutdown Reset: 

Set operating mode switch to “OFF” and 

remove some of the connected electrical load (ie: turn off some of the AC 
devices drawing power which may have caused the overload of the unit). 

Wait one minute, then switch operating mode switch back to either 

“REMOTE” or “ON.”

Output Circuit Breaker Reset (Select Models): 

Alternatively, check 

output circuit breaker(s) on the unit's front panel. If tripped, remove some 

of the electrical load, then wait one minute to allow components to cool 

before resetting the circuit breaker. See Troubleshooting for other possible 

reasons AC output may be absent.

Set Battery Charge Conserver (Load Sense) Dial

In order to save battery power, the Inverter automatically 
shuts off in the absence of any power demand from 

connected equipment or appliances (the electrical load). 

When the unit detects a load, it automatically turns on. 

Users may choose the minimum load the Inverter will 
detect by adjusting the Battery Charge Conserver Dial 
(see diagram). Using a small tool, turn the dial clockwise to lower the 

minimum load that will be detected, causing the Inverter to turn on for 
smaller loads. When the dial is turned fully clockwise, the Inverter will 
operate even when there is no load. Turn the dial counterclockwise to set a 
higher minimum load, causing the Inverter to stay off until the new 
minimum load is reached. When the dial is turned fully counterclockwise, 
the Inverter will turn on when it detects any load greater than 

approximately 150 Watts.

Note: The factory setting for the dial is fully clockwise. However, based on the threshold load to 
which you’d like the Inverter to respond, you should adjust the dial counterclockwise to reduce 
its sensitivity until the Inverter is active only when connected equipment or appliances are actu-
ally in use.

Connect Remote Control—OPTIONAL 

(included with the PV3000GFCI)

All models feature an 8-conductor telephone style receptacle on the front 
panel for use with an optional remote control module (Tripp Lite model 
APSRM4, sold separately or included with PV3000GFCI model). The 

remote module allows the Inverter to be mounted in a compartment or 

cabinet out of sight, while operated conveniently from your vehicle’s 
dashboard. See instructions packed with the remote control module.

REMOTE

OFF

ON

REMOTE

OFF

ON

REMOTE

OFF

ON

1

2

3

4

5

6

7

1

2

3

4

5

LOAD 

SENSE

GREATER 

LOAD 

ON

LESSER
LOAD 
ON

Содержание PowerVerter

Страница 1: ...emark of Tripp Lite All rights reserved Application Guide 5 Safety 2 Introduction 2 Mounting 5 Feature Identification 3 Battery Connection 6 Operation 4 Troubleshooting Service Maintenance Warranty 7 Warranty Registration 8 W a r r a n t y R e g i s t r a t i o n R e g i s t e r o n l i n e t o d a y f o r a c h a n c e t o w i n a F R E E T r i p p L i t e p r o d u c t w w w t r i p p l i t e c ...

Страница 2: ...nd Connection Warnings Safe operation requires connecting the Inverter s Main Ground Lug directly to the frame of the vehicle or earth ground Equipment Connection Warnings Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recom...

Страница 3: ...e to overload PV3000GFCI model includes two separate 20 amp circuits See Operation for resetting instructions 7 Remote Control Module Connector allows remote monitoring and control with an optional module Tripp Lite model APSRM4 sold separately or included with PV3000GFCI model See remote module owner s manual for connection instructions 8 Battery Charge Conserver Load Sense Dial conserves battery...

Страница 4: ...harge battery When battery is adequately charged switch operating mode switch back to either REMOTE or ON Overload Shutdown Reset Set operating mode switch to OFF and remove some of the connected electrical load ie turn off some of the AC devices drawing power which may have caused the overload of the unit Wait one minute then switch operating mode switch back to either REMOTE or ON Output Circuit...

Страница 5: ...ings while batteries discharged in 9 minutes provide as little as 30 of their amp hour ratings You must allow your batteries to recharge long enough to replace the charge lost during Inverter operation or else you will eventually run down your batteries NOTE For Tripp Lite Inverters over 1000 watts used in mobile applications Tripp Lite recommends you use at least two batteries if possible fed by ...

Страница 6: ...ry to all four DC terminals In this connection you must run 4 wires of equal length between the inverter and the battery Length Gauge of Cables Although your Inverter is a high efficiency converter of electricity its rated output capacity is limited by the length and gauge of the cabling running from the battery to the unit Use the shortest length and largest diameter cabling maximum 00 gauge to f...

Страница 7: ...plite com support Before returning your product for service follow these steps 1 Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading of the instructions 2 If the problem continues do not contact or return the product to the dealer Instead visit www tripplite com support 3 If the problem requires service visit www t...

Страница 8: ... therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically Tripp Lite is not liable for any costs such as lost profits or revenue loss of equipmen...

Отзывы: