background image

2

Important Safety Instructions

Introduction

SAVE THESE INSTRUCTIONS!

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite 
Inverters.

Location Warnings

•    Install your Inverter in a location or compartment in your vehicle that minimizes exposure to heat, dust, direct sunlight and moisture. Flooding the unit 

with water will cause it to short circuit and could cause personal injury due to electric shock.

•    Leave a minimum of 2" clearance at front and back of the Inverter for proper ventilation. To avoid overheating the Inverter, any compartment that 

contains the Inverter must be properly ventilated with adequate outside air flow. The heavier the load of connected equipment, the more heat will be 
generated by the unit.

•    Do not install the Inverter directly near magnetic storage media, as this may result in data corruption.
•    Do not install near flammable materials, fuel or chemicals.
•  Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the unit’s internal cooling, 

eventually causing product damage not covered under warranty.

Battery Connection Warnings

•    Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.
•    Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be installed in a “dead 

air” compartment. Ideally, any compartment would have some ventilation to outside air. 

•    Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.
•    Do not allow objects to contact the DC input terminals. Do not short or bridge these terminals together. Serious personal injury or property damage 

could result.

Ground Connection Warnings

•   Safe operation requires connecting the Inverter's Main Ground Lug directly to the frame of the vehicle or earth ground.

Equipment Connection Warnings

•    Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life 

support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a 
flammable anesthetic mixture with air, oxygen or nitrous oxide.

•    Do not connect surge suppressors, line conditioners or UPS systems to the output of the inverter which contains TVSS (Transient Voltage Surge 

Suppressors) or damage will occur.

Operation Warnings

•    Your Inverter does not require routine maintenance.
•    Potentially lethal voltages exist within the Inverter as long as the battery supply is connected. During any service work, the battery supply should 

therefore be disconnected.

•   Do not connect or disconnect batteries while the Inverter is operating from the battery supply. Dangerous arcing may result.

Reliable AC Power Wherever You Need It!

Congratulations! You’ve purchased the most advanced, feature-rich Inverter designed as a mobile energy source for your vehicle. PowerVerter Inverters 
efficiently convert DC (battery) power into 120V AC (household) power, allowing you to use equipment you commonly use at home—appliances, 
entertainment systems, computers, power tools and more—while cruising the open road or out on the open water. PowerVerter Inverters, through a high-
efficiency conversion process and a charge conservation setting, draw the highest level of performance from your batteries without overtaxing them, 
lengthening their service life. An automatic low battery shutdown feature ensures you'll always have plenty of power for starting purposes.

•  Automatic Overload Protectio

n

• Automatic “Battery-Saver” Low Voltage Shutdown
•  High Efficiency DC-to-AC Inversion
•  Multi-Function Lights & Switches
•   Optional Remote Control Capability 

(Module included with PV3000GFCI)

Содержание PowerVerter

Страница 1: ...emark of Tripp Lite All rights reserved Application Guide 5 Safety 2 Introduction 2 Mounting 5 Feature Identification 3 Battery Connection 6 Operation 4 Troubleshooting Service Maintenance Warranty 7 Warranty Registration 8 W a r r a n t y R e g i s t r a t i o n R e g i s t e r o n l i n e t o d a y f o r a c h a n c e t o w i n a F R E E T r i p p L i t e p r o d u c t w w w t r i p p l i t e c ...

Страница 2: ...nd Connection Warnings Safe operation requires connecting the Inverter s Main Ground Lug directly to the frame of the vehicle or earth ground Equipment Connection Warnings Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recom...

Страница 3: ...e to overload PV3000GFCI model includes two separate 20 amp circuits See Operation for resetting instructions 7 Remote Control Module Connector allows remote monitoring and control with an optional module Tripp Lite model APSRM4 sold separately or included with PV3000GFCI model See remote module owner s manual for connection instructions 8 Battery Charge Conserver Load Sense Dial conserves battery...

Страница 4: ...harge battery When battery is adequately charged switch operating mode switch back to either REMOTE or ON Overload Shutdown Reset Set operating mode switch to OFF and remove some of the connected electrical load ie turn off some of the AC devices drawing power which may have caused the overload of the unit Wait one minute then switch operating mode switch back to either REMOTE or ON Output Circuit...

Страница 5: ...ings while batteries discharged in 9 minutes provide as little as 30 of their amp hour ratings You must allow your batteries to recharge long enough to replace the charge lost during Inverter operation or else you will eventually run down your batteries NOTE For Tripp Lite Inverters over 1000 watts used in mobile applications Tripp Lite recommends you use at least two batteries if possible fed by ...

Страница 6: ...ry to all four DC terminals In this connection you must run 4 wires of equal length between the inverter and the battery Length Gauge of Cables Although your Inverter is a high efficiency converter of electricity its rated output capacity is limited by the length and gauge of the cabling running from the battery to the unit Use the shortest length and largest diameter cabling maximum 00 gauge to f...

Страница 7: ...plite com support Before returning your product for service follow these steps 1 Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading of the instructions 2 If the problem continues do not contact or return the product to the dealer Instead visit www tripplite com support 3 If the problem requires service visit www t...

Страница 8: ... therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically Tripp Lite is not liable for any costs such as lost profits or revenue loss of equipmen...

Отзывы: