Operation

Switch Modes

After configuring, mounting and connecting your Inverter/Charger,
you are able to operate it by switching between the following oper-
ating modes as appropriate to your situation:

AUTO/REMOTE:

Switch to this mode when you

need constant, uninterrupted AC power for connected
appliances and equipment. The Inverter/Charger will
continue to supply AC power to connected equipment
and to charge your connected batteries while utility-
or generator-supplied AC power is present. Since the inverter is ON
(but in Standby) in this mode, it will automatically switch to your
battery system to supply AC power to connected equipment in the
absence of a utility/generator source or in over/under voltage situa-
tions. “AUTO/REMOTE” also enables an optional remote control
module (Tripp Lite model APSRM4, sold separately or included
with select models) to function when connected to the unit.

CHARGE ONLY

: Switch to this mode when you

are not using connected appliances and equipment in
order to conserve battery power by disabling the
inverter. The Inverter/Charger will continue to sup-
ply AC power to connected equipment and charge
connected batteries while utility- or generator-sup-
plied AC power is present. However, since the inverter is OFF in this
mode, it WILL NOT supply AC power to connected equipment in
the absence of a utility/generator source or in over/under voltage sit-
uations.

DC OFF:

Switch to this mode to prevent the invert-

er from drawing power from the batteries. Use this
switch to automatically reset the unit if it shuts down
due to overload or overheating. First remove the
excessive load or allow the unit to sufficiently cool
(applicable to your situation). Switch to "DC OFF", then back to
"AUTO/REMOTE" or "CHARGE ONLY" as desired. If unit fails to
reset, remove more load or allow unit to cool further and retry. Use
an optional remote control module (Tripp Lite model APSRM4, sold
separately) to reset unit due to overload and overtemperature.

CAUTION: The unit will always pass AC power through to con-
nected equipment if plugged into a live AC outlet, regardless of
the position of the Operating Mode Switch.

Indicator Lights

Your Inverter/Charger (as well as an optional Tripp Lite Remote
Control Module, sold separately or included with select models) is
equipped with a simple, intuitive, user-friendly set of indicator
lights. These easily-remembered “traffic light” signals will allow
you, shortly after first use, to tell at a glance a wide variety of oper-
ating details.

“LINE Green LED”:

If the operating mode switch is

set to “AUTO/REMOTE”, this light will ILLUMI-
NATE CONTINUOUSLY when your connected
equipment is receiving continuous AC power sup-
plied from a utility/generator source.

If the operating mode switch is set to “CHARGE ONLY”, this light
will BLINK to alert you that the unit’s inverter is OFF and will NOT
supply AC power in the absence of a utility/generator source or in
over/under voltage situations.

“INV” (Inverting) Yellow LED: 

This light will

ILLUMINATE CONTINUOUSLY whenever con-
nected equipment is receiving battery-supplied,
inverted AC power (in the absence of a utility/gener-
ator source or in over/under voltage situations). This

light will be off when AC power is supplying the load. This light
will BLINK to alert you if the load is less than the Battery Charge
Conserver (Load Sense) setting.

“LOAD” Red LED: 

This red light will ILLUMI-

NATE CONTINUOUSLY whenever the inverter is
functioning and the power demanded by connected
appliances and equipment exceeds 100% of load
capacity. The light will BLINK to alert you when the
inverter shuts down due to a severe overload or overheating. If this
happens, turn the operating mode switch “OFF”; remove the over-
load and let the unit cool. You may then turn the operating mode
switch to either “AUTO/REMOTE” or “CHARGE ONLY” after it
has adequately cooled. This light will be off when AC power is sup-
plying the load. 

"BATT VOLTAGE" LEDs: 

If the operating mode switch is in the

"AUTO/REMOTE" or "CHARGE ONLY" position, the LEDs indi-
cate the approximate charge level and voltage of your connected
battery bank and alert you to several fault conditions. See Chart for
charge and voltage levels.

LED Function with Switch in "AUTO/REMOTE" or “Charge
Only” Position

Approximate Battery Charge Level*

LEDs

Battery Capacity

Illuminated

(Charging/Discharging)

Green

91%–Full

Green & Yellow

81%–90%

Yellow

61%–80%

Yellow & Red

41%–60%

Red

21%–40%

All three lights off

1%–20%

Flashing red

0% (Inverter 
shutdown)**

* Charge levels listed are approximate. Actual conditions vary 
depending on battery condition and load. ** Inverter shutdown protects battery against damage
due to  excessive discharge.

Fault Condition

LEDs

Fault 

Illuminated

Condition

All three lights 

Excessive discharge 

flash slowly*

(Inverter shutdown)

All three lights 

Overcharge (Charger 

flash quickly**

shutdown)

*Approximately ½ second on, ½ second off. See Troubleshooting section. Inverter shutdown
protects battery against damage due to excessive discharge.** Approximately ¼ second on, ¼
second off. Charger shutdown protects battery against damage due to overcharge. May also
indicate a battery charger fault exists. See Troubleshooting section.

1

2

3

4

5

6

7

1

2

1

2

3

4

5

6

7

1

2

4

200712159 93-2768 RV Series Inverter-Charger Owner’s Manual_Eng.qxd  2/29/2008  1:55 PM  Page 4

Содержание PowerVerter Dc-to-AC

Страница 1: ...All Loads Frequency Controlled Output Automatic Load Switching Balanced Load Sharing Better for Your Batteries Faster Battery Recharge High Amp 3 Stage Battery Charger adjustable Critical Battery Pro...

Страница 2: ...ut terminals Do not short or bridge these terminals together Serious personal injury or property damage could result Equipment Connection Warnings Use of this equipment in life support applications wh...

Страница 3: ...lectrical system input and recommended GFCI receptacle output See AC Input Output Connection section for instructions Resettable Circuit Breakers protect your Inverter Charger against damage due to ov...

Страница 4: ...switch is set to AUTO REMOTE this light will ILLUMI NATE CONTINUOUSLY when your connected equipment is receiving continuous AC power sup plied from a utility generator source If the operating mode sw...

Страница 5: ...Position 105V A4 Up A3 Up 95V A4 Up A3 Down 85V A4 Down A3 Up 75V A4 Down A3 Down factory setting A1 A2 A3 A4 A1 A2 A3 A4 A1 A2 A3 A4 A1 A2 A3 A4 A3 A4 Most of your connected appliances and equipment...

Страница 6: ...h is momentarily engaged to begin the process of equalizing the charge state of your battery s cells by time limited overcharge of all cells This can extend the useful life of certain types of batteri...

Страница 7: ...ne is started Connect Battery Temperature Sensing Cable OPTIONAL The battery temperature sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature...

Страница 8: ...r batteries with utility or generator supplied AC power Compensate for inefficiency by multiplying this number by 1 2 This will give you a rough estimate of how many amp hours of battery power from on...

Страница 9: ...Charger s nameplate See diagrams on page 9 for proper fuse placement Connect your Inverter Charger to your batteries using the following procedures WARNING Failure to properly ground your Inverter Cha...

Страница 10: ...ng wires to the hot black neutral white and ground green terminals Replace cover plate and tighten screws If the incoming conduit only contains two wires hot and neutral the incoming conduit must be b...

Страница 11: ...osition However if an external charger is used to recharge the batteries you will need to manually reset the unit by moving the Operating Mode Switch to DC OFF for two seconds then returning it to AUT...

Страница 12: ...93 2768 1111 W 35th Street Chicago IL 60609 USA Customer Support Support la client le 773 869 1234 www tripplite com 200712159 93 2768 RV Series Inverter Charger Owner s Manual_Eng qxd 2 29 2008 1 55...

Отзывы: