Indicator Lights

All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned on.

This green light will turn ON whenever your UPS is plugged in and
receiving normal AC line power.

This red light will turn ON when your UPS is providing your
equipment with battery power.

This yellow light will turn ON continuously after you test your UPS
battery’s charge with the “MUTE/TEST” Switch if the UPS’s battery
is less than fully charged. If it stays on continuously, contact Tripp
Lite for service. The light will flash after you set the “OFF/ON”
Switch to the “OFF” position to indicate that the UPS will not
provide battery backup during a blackout or brownout.

Whenever your UPS is automatically correcting high or low AC line
voltage, this green light will turn ON and the UPS will gently click.
The more the UPS has to correct voltage, the more the green light
will turn ON and the more the UPS will click. These are both
normal, automatic operations of your UPS, and no action is
required on your part.

Other UPS Features

AC Receptacles

The “battery supported” receptacles on your UPS provide your
connected equipment with AC line power during normal opera-
tion and with battery power during blackouts and brownouts.
They also protect your equipment against damaging surges and
line noise. The “surge-only” receptacles  provide peripherals with
surge protection without committing precious battery power to
support them during blackouts.

RJ11 Telephone Jacks

These jacks protect your equipment against telephone line
surges. Connecting your equipment to these jacks is optional.
Your UPS will still work properly without this connection.

DB9 Port

The DB9 port connects your UPS to any workstation or server.
Use with Tripp Lite software and cabling to automatically save
open files and shut down equipment during a blackout. This port
sends contact-closure signals to indicate line-fail and low-
battery status. Contact Tripp Lite Customer Support for more
information.

Battery Replacement Door

Under normal conditions, the original battery in your UPS will
last several years. Battery replacement should be performed
only by qualified service personnel. Refer to “Battery Warnings” in
the Safety section on page 2.

200006025 OmniSmart 725 for CostCo.p65

6/8/00, 3:02 PM

5

Содержание OmniSmart 725

Страница 1: ...Copyright 2000 Tripp Lite All rights reserved OmniSmart is a trademark of Tripp Lite Owner sManual OMNISMART 725 Line InteractiveUPSSystem 120V ESPA OL p 7 FRAN AIS p 14 Quick Installation p 3 Basic O...

Страница 2: ...ilure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors to the output of your UPS This may damage your UPS...

Страница 3: ...tions and Setting Advantages OptionalInstallation OPTION1 Phone LineSurgeSuppression Using telephone cords connect your wall jack to the UPS jack marked LINE or IN Connect your equipmenttotheUPSjackma...

Страница 4: ...C power from battery Note When the battery is nearly depleted the Low Battery alarm a continuous beep that cannot be silenced will alert you to immediately shut down connected equipment Test your UPS...

Страница 5: ...on your part Other UPS Features AC Receptacles The battery supported receptacles on your UPS provide your connected equipment with AC line power during normal opera tion and with battery power during...

Страница 6: ...ipment operationsorproceduresthat could affect the proper operation of your equipment If it does you will be given advance notice to give you an opportunity to maintain uninterruptedservice Ifyouexper...

Страница 7: ...iedad literaria de Tripp Lite Reservados todos los derechos OmniSmart es una marca registrada de Tripp Lite Manual de Operaci n OMNISMART 725 No break SistemaUPSInteractivo 120V Instalaci n R pida p 9...

Страница 8: ...ausar anomal as o alterar significativamente el rendimiento del dispositivo de soporte de vida No conecte supresores de sobretensiones transitorias a los recept culos de salida de este no break sistem...

Страница 9: ...Refi rase a la secci n Instalaci n B sica para obtener informaci n sobre las funciones de este interruptor condiciones del no break sistema UPS y las ventajas de cada posici n 2 1 3 OPCION 2 Software...

Страница 10: ...izar tres funciones Silenciar de la alarma de apagones Mueva este interruptor hacia la izquierda y su ltelo hasta que el no break sistema UPS emita un leve sonido aproximadamente 2 segundos para desac...

Страница 11: ...ici n OFF apagado para indicarle que el no break sistema UPS no suministrar energ a de bater a durante una ca da de voltaje o interrupci n en el suministro de la energ a el ctrica Esta luz verde se en...

Страница 12: ...conexi n de sus equipos a estos contactos telef nicos es opcional Este no break sistema UPS funcionar correctamente a n sin esta conexi n Puerto DB9 El puerto DB9 conecta el no break sistema UPS a cu...

Страница 13: ...ficaci n Esteequipohapasadotodaslaspruebasdeconformidadconlosl mitesdedispositivosdigitalesdelaClaseBdeacuerdocon laParte15delaRegulacionesdeFCC Comit FederaldeComunicaciones Estosl miteshansidodise a...

Страница 14: ...anuel de l Utilisateur OMNISMART 725 Syst me d UPS Ligne Interactive 120V Installation Rapide p 16 Op ration de Base p 17 19 Entreposage Service p 19 Caract ristiques p 20 S ret p 15 Warranty Insuranc...

Страница 15: ...elles un d faut de fonctionnement ou une panne d un syst me d UPS de Tripp Lite pourrait causer la panne ou pourrait modifier de mani re significative l ex cution d un dispositif de support vie Ne con...

Страница 16: ...onnect Se reporter la section Op rations de Base pour la Fonction du Commutateur Etat de l UPS et Avantages de la Configuration 2 1 3 Les connexions du port DB9 et de la ligne t l phonique sont facult...

Страница 17: ...termittence lorsque l onduleur est en train de fournir l alimentation C A partir de la batterie Note Lorsque la batterie est presque puis e l alarme Batterie Faible un signal continu qui ne peut pas t...

Страница 18: ...UPS est branch et re oit la puissance normale de ligne C A Ce voyant rouge s allumera quand votre syst me d UPS fournit votre mat riel la puissance de batterie Ce voyant jaune s allumera sans interrup...

Страница 19: ...merciale re u de ventes Prises Jacks de t l phone RJ11 Ces jacks prot gent votre mat riel contre les surtensions sur votre ligne t l phonique Relier votre mat riel ces prises jacks est facultatif Votr...

Страница 20: ...squ cequeleprobl meait t corrig oudevoussoyezs rquelemat rielfonctionnecorrectement Iln yaaucune r parationconcernantleprotecteurdeModem Faxquipuissent treeffectu eparleclient Cemat rielnepeut treutil...

Отзывы: