background image

5

Important Safety Instructions

Connection and Start-Up

Plug your UPS’s line cord into an
electrical outlet.

Your UPS must be connected to a dedicated
circuit of sufficient amperage. Note, however,
that the select models may be fitted with
different plug types. Refer to the “OP Rating/
Plug Rating” chart printed on the top of your
UPS.

Once your UPS is plugged in, the fan and all
Indicator Lights will turn ON. The “LINE” and
“LOAD ACTIVE METER” LEDs will illuminate
and the UPS will emit a beep to indicate normal
operation. However, power is not supplied to
your UPS’s AC outlets until the UPS is turned on.

Plug your equipment into your UPS.

Your UPS is designed to support audio/video
systems and their associated servers, Media
Center PCs, and a Tripp Lite HT3100PC Power
Conditioning Center only. The total number of
components connected should not exceed UPS
capacity. This will overload your UPS system.
You will also overload your UPS if you connect
household appliances to the UPS's outlets.

Turn your UPS ON:

• Press the “ON/TEST” Button 
• Hold it for several seconds until you hear 

a beep

• Release it

Your UPS will begin providing AC power to its outlets. 
The “ON LINE” LED will illuminate.

Your UPS will function properly without these
connections. 

Phone Line or Phone/Network
Line Surge Suppression

Your UPS has jacks which protect against
surges on a phone line. Select models feature
jacks which also protect against surges on a
network line.* Using appropriate telephone or
network cords connect your wall jack to the
UPS jack marked “IN.” Connect your
equipment to the UPS jack marked “OUT.”
Make sure the equipment you connect to the
UPS's jacks is also protected against surges on
the AC line.

* Not compatible with PoE (Power Over Ethernet) applications.

Your model may differ.

1

1

2

3

2

3

Your model may differ.

Installation 

(continued)

Optional Connections

1

1

Your model may differ.

200507084 93-2474 SMARTONLINE HT OM.qxd  10/20/2005  11:11 AM  Page 5

Содержание Audio/Video On-Line UPS System

Страница 1: ...ce 14 Audio Video True On Line UPS Systems Intelligent True On Line Operation Pure Sine Wave Output Zero Transfer Time 1000VA 2200VA Capacities Extended Run Options Warranty Registration 14 Copyright...

Страница 2: ...he other end of this cord The UPS itself must be directly connected to a properly grounded wall outlet The total number of components connected should not exceed the UPS capacity This will overload yo...

Страница 3: ...justable rackmount shelf kit skip steps 1 and 2 Connect the two segments of each shelf using the included screws and nuts Leave the screws slightly loose so that the shelves can be adjusted in the nex...

Страница 4: ...r position with optional base stands sold separately by Tripp Lite Model 2 9USTAND When mounting the UPS on adjustable base stands make sure that the control panel is toward the top The control panel...

Страница 5: ...hould not exceed UPS capacity This will overload your UPS system You will also overload your UPS if you connect household appliances to the UPS s outlets Turn your UPS ON Press the ON TEST Button Hold...

Страница 6: ...e to a user supplied normally closed or normally open switch according to the circuit diagram see The EPO port is not a phone line surge suppressor do not connect a phone line to this port External Ba...

Страница 7: ...The UPS will continue charging and the fan will continue to cool internal components even after you turn the UPS receptacles off To turn the UPS OFF completely including the charger disconnect the UPS...

Страница 8: ...ndicate that the set of four dual function LEDs is displaying the load level of your UPS BATT ACTIVE METER LED This green light will illuminate when your UPS is operating from battery power to indicat...

Страница 9: ...Lite Battery Packs for additional runtime Contact Tripp Lite Customer Support at 773 869 1234 for the appropriate Tripp Lite battery pack to connect Refer to instructions available with the Battery P...

Страница 10: ...r RS 232 These ports connect your UPS to any Media Center PC or home automation system Use with Tripp Lite s PowerAlert Software and included cables to enable your Media Center PC home automation syst...

Страница 11: ...the UPS output On FAULT Check the utility line for wiring problems Condition Wiring Fault such as reversed line and neutral or a missing ground On FAULT 100 Restart the UPS If the problem persists Con...

Страница 12: ...High Output Voltage and Abnormal Input On FAULT Restart the UPS If the problem persists Flashing LINE 50 contact Tripp Lite for repairs Condition No Output due to Low Output Voltage and Abnormal Inpu...

Страница 13: ...or hot swap replacement i e leaving the UPS in ON mode but some qualified service personnel may wish to put the UPS in the OFF mode and disconnect equipment before proceeding Procedure Remove Front Pa...

Страница 14: ...s Only If your Modem Fax Protection causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance If advance notice is...

Страница 15: ...15...

Страница 16: ...1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com 200507084 93 2474...

Отзывы: