SAVE THESE INSTRUCTIONS

This manual contains instructions and warnings that should be 

followed during the installation, operation and storage of this 

product. Failure to heed these instructions and warnings will 

void the product warranty.

CAUTION

 Only those who are properly trained or qualified to use this device 

should do so. Anyone who is not trained or qualified should not use this device 

unless it is under the supervision of someone who is properly trained or qualified 

to do so. Children must be supervised to ensure that they do not use the device 

as a toy.

Never use the device if the cord and plug are damaged; if it is not working 

properly, or if it has been dropped or damaged, take it to an authorized service 

center for inspection and repair.

If the power cord is damaged, it must be replaced by the manufacturer, its 

authorized service agent, or by qualified personnel in order to avoid a danger.

•   The PDUMV30-ISO PDU model provides surge and line noise protection to connected 

equipment through its outlets.

•  Non-ISO PDUs do not provide surge and line protection to connected equipment.

•  The PDU is designed for indoor use only in a controlled environment away from excess 

moisture, temperature extremes, conductive contaminants, dust or direct sunlight.

•   The PDU must be installed by a qualified technician only.

•   Install in accordance with National Electrical Code standards. Be sure to use the proper 

overcurrent protection for the installation, in accordance with the plug/equipment rating.

•   Connect the PDU to an outlet that is in accordance with your local building codes and 

adequately protected against excess currents, short circuits, and earth faults.

•   Keep indoor ambient temperatures between 32°F and 77°F (0°C and 25°C).

•  Use of this equipment in life support applications where failure of this equipment can 

reasonably be expected to cause the failure of the life support equipment or to 

significantly affect its safety or effectiveness is not recommended. Do not use this 

equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous 

oxide.

•  Do not connect the PDU to an ungrounded outlet or extension cords or adapters that 

eliminate the connection to ground.

•  The power requirement for each piece of equipment connected to the PDU must not 

exceed the individual outlet’s load rating.

•   The plug on the power supply cord serves as the disconnect device.

•   The electrical outlets that supply power to the equipment should be near the equipment 

and easily accessible.

•  The total power requirement for equipment connected to the PDU must not exceed the 

maximum load rating for the PDU.

Important Safety Instructions

Important Warnings

Содержание AGIB6672

Страница 1: ...74 Important Safety Instructions 2 Important Warnings 2 Installation 3 Features 4 Warranty Product Registration 5 Espa ol 6 Fran ais 11 16 1111 W 35th Street Chicago IL 60609 USA tripplite com support...

Страница 2: ...minants dust or direct sunlight The PDU must be installed by a qualified technician only Install in accordance with National Electrical Code standards Be sure to use the proper overcurrent protection...

Страница 3: ...common rack and rack enclosure types and may not be appropriate for all applications 1A Zero U Rack Configuration Mounting Brackets Prior to installation determine the rack location in which the PDU i...

Страница 4: ...of the surge suppression components are not functioning and the unit should be returned for repair as soon as possible You may still use the unit however connected equipment will be protected from spi...

Страница 5: ...diction to jurisdiction WARNING The individual user should take care to determine prior to use whether this device is suitable adequate or safe for the use intended Since individual applications are s...

Страница 6: ...DUMV20HV PDUMV20HVL6 PDUMV20HV 36 PDUV20HVL6 72 N mero de Serie AGIB6672 AGPD6673 AGPD6674 Instrucciones de seguridad 7 importantes Advertencias importantes 7 Instalaci n 8 Caracter sticas 9 Garant a...

Страница 7: ...ras extremas contaminantes conductores polvo o luz solar directa El PDU debe ser instalado solamente por un t cnico calificado Instale conforme a los est ndares del C digo El ctrico Nacional Aseg rese...

Страница 8: ...a racks bastidores y cajas de rack bastidor comunes y pueden no ser apropiados para todas las aplicaciones 1A Configuraci n Cero U para Rack Soportes de Montaje Antes de la instalaci n determine la ub...

Страница 9: ...ontra de las sobretensiones e impulsos par sitos Este LED debe encenderse siempre que se conecte el PDU y est presente la energ a Si no se enciende el LED que indica que la protecci n se encuentra pre...

Страница 10: ...o es apropiado adecuado o seguro para el uso proyectado Ya que las aplicaciones individuales est n sujetas a gran variaci n el fabricante no declara ni garantiza en lo que se refiere a la idoneidad o...

Страница 11: ...0 ISO PDUMV20HV PDUMV20HVL6 PDUMV20HV 36 PDUV20HVL6 72 Num ro de s rie AGIB6672 AGPD6673 AGPD6674 Importantes consignes 12 de s curit Importantes mises en garde 12 Installation 13 Caract ristiques 14...

Страница 12: ...s et les d fauts la terre Maintenir la temp rature int rieure ambiante entre 0 C et 25 C 32 F et 77 F Il est d conseill d utiliser cet quipement dans des applications m dicales o une panne de cet quip...

Страница 13: ...figuration en baie z ro U Supports de montage Avant l installation d terminer l emplacement de la baie dans laquelle l unit de distribution d alimentation PDU doit tre install e Fixer les supports de...

Страница 14: ...rait tre allum chaque fois que la PDU est branch e et qu elle est sous tension Si le voyant Limiteur en fonction ne s illumine pas certains des composants de protection contre la surtension ne fonctio...

Страница 15: ...iner avant utilisation si cet appareil est appropri ad quat ou offre toute s curit pour l utilisation pr vue Du fait que les applications individuelles sont sujettes de grandes variations le fabricant...

Страница 16: ...PDUV30HV PDUV30 36 PDUMV30 ISO PDUMV20HV PDUMV20HVL6 PDUMV20HV 36 PDUV20HVL6 72 AGIB6672 AGPD6673 AGPD6674 17 17 18 19 20 English 1 Espa ol 6 Fran ais 11 1111 W 35th Street Chicago IL 60609 USA trippl...

Страница 17: ...17 PDU PDU ISO PDU PDU PDU 0 25 C PDU PDU PDU PDU PDU...

Страница 18: ...672 30 A PDUV20HVL6 72 AGIB6672 20 A PDUMV30 PDUMV30 ISO AGPD6673 30 A PDUMV16HV PDUMV20HV PDUMV20HVL6 PDUMV20HV 36 AGPD6674 20 A PDUMV30HV AGPD6675 30 A PDU 1A 0U PDU PDU PDU PDU 1B 0U PDU PDU PDU 1C...

Страница 19: ...DUV20HVL6 72 PDUMV20HVL6 PDUMV20HV 36 PDUMV30HV PDUV30HV 3 C19 PDUMV20HV PDUV20HVL6 72 PDUMV20HVL6 PDUMV20HV 36 PDUMV30HV PDUV30HV 4 L5 30P L6 20P L6 30P 5 PDU 6 PDU 7 Protection Present PDU Protectio...

Страница 20: ...5th Street Chicago IL 60609 USA tripplite com support Tripp Lite Tripp Lite 1111 W 35th Street Chicago IL 60609 USA tripplite com support 22 01 161 932685_RevJ Line Fault PDU Line Fault Line Fault PDU...

Отзывы: