background image

WireMaster

Mapper

8-Way Wire &

Cable Mapping Kit

Instruction Manual

TRIPLETT

84-876

3/09

Test Equipment Depot - 800.517.8431 

99 Washington Street, Melrose, MA 02176 

TestEquipmentDepot.com  

Содержание WireMaster Mapper

Страница 1: ...WireMaster Mapper 8 Way Wire Cable Mapping Kit Instruction Manual TRIPLETT 84 876 3 09 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Страница 2: ...onnect directly to BNC cables Male to Male BNC Adaptor included 8 F Remotes included can connect directly to Cable TV F cables Male BNC to Female F Adaptor included Male F to Male F Adaptor included 8...

Страница 3: ...attery included Power Latch Function Switch to prevent accidental turn ons Use BNC Remotes to identify coaxial cables in CCTV Security and Surveillance systems Broadcast TV and Residential Video syste...

Страница 4: ...to perform its intended function and to prevent accidental damage to the product i e while the WireMaster Mapper detects the presence of 120VAC it is not safe while doing so The product and its conne...

Страница 5: ...no minimum Maximum Cable Length any length whose total DC resistance is less than 200 Ohms see table for some common examples Cables Wires Tested Any pair whose total DC resistance is less than 200 Oh...

Страница 6: ...sformers Baluns Modulators DC Blockers Power Dividers Directional Taps Splitters non power passive Note The WireMaster Mapper does not perform complete tests of all conductors in a cable Its function...

Страница 7: ...1 5 t f 0 0 9 3 U 9 5 G R 9 5 6 9 n e d l e B s m h O 6 7 1 t f 0 0 3 1 1 x a o C i n i M 1 2 2 9 n e d l e B s m h O 1 1 1 t f 0 0 8 1 3 T A C e n o h p e l e T 1 A 7 2 2 1 n e d l e B s m h O 6 5 t...

Страница 8: ...8 5 CONTROL LOCATIONS C A B F E D G A Open LED E 1 thru 8 ID LED s B Unlock Button F Short Continuity LED C Function Switch G BNC Connector D Overload Voltage LED...

Страница 9: ...ture to prevent the product from accidentally being turned on which could result in a dead battery Note that the Function switch is locked into the OFF OVERLOAD VOLTAGE position To turn the product on...

Страница 10: ...pper In use thousands of feet of wire may be between the Remote and the WireMaster Mapper and the Re mote will cause the appropriate LED to light 7 DETAILED OPERATION Identifying Cables Mapping The Wi...

Страница 11: ...riate adaptor connect the WireMaster Mapper with its Function switch set to OFF OVERLOAD VOLTAGE to each of the cables to be mapped If there is an AC or DC plus voltage present the OVER LOAD VOLTAGE i...

Страница 12: ...plitters amplifiers or any other DC blocking devices If the SHORT CONTINUITY LED lights and the beeper sounds the cable may be shorted or some device is connected to the cable that appears as a short...

Страница 13: ...the Remote location and at the WireMaster Mapper location single wires can be ID ed Connect one alligator clip at both locations to the ground Connect the other clip to the wire s to be ID ed ID the...

Страница 14: ...rections Because of this behavior the Remote can be connected to any port on the splitter and it can be seen on any other port A typical test would be to connect the chosen Remote to the input of the...

Страница 15: ...ed RJ connectors While these may look like standard RJ11 con nectors they are a special type that can be plugged into either RJ11 or RJ45 jacks If a standard RJ11 connector is plugged into an RJ45 con...

Страница 16: ...sly testing the target cable for the presence of a Re mote some products only perform a momentary test When a cable is suspected of having an intermittent connection a Re motecanbeconnectedtooneendoft...

Страница 17: ...signal is compatible with the Triplett Hound Hound 2 and Hound 3 To trace a wire using this feature connect the WireMaster Mapper to the cable or pair of wires using one of the provided adaptors and t...

Страница 18: ...emote 4 3274 4 BNC Remote 5 3274 5 BNC Remote 6 3274 6 BNC Remote 7 3274 7 BNC Remote 8 3274 8 Male BNC to Male BNC Adaptor 13838 F Remote 1 RMT F F 1 F Remote 2 RMT F F 2 F Remote 3 RMT F F 3 F Remot...

Страница 19: ...MT RJ M 8 Male BNC to Male RJ11 RJ45 Adaptor BNC M RJ M Female Female RJ11 Coupler RJ11 F RJ11 F Female Female RJ45 Coupler 2455 781 Clip Lead Remote 1 RMT CLIP 1 Clip Lead Remote 2 RMT CLIP 2 Clip Le...

Страница 20: ...ble BNC Remotes 1 8 3274 9 F Remotes 1 8 RMT F F 9 RJ11 RJ45 Remotes 1 8 RMT RJ M 9 Clip Lead Remotes 1 8 RMT CLIP 9 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipme...