Specifications 

  

Function 

 

Range and Resolution 

 

Accuracy 

Humidity 

 

0.0 to 100.0% RH 

 

±3% RH (10 to 90%) 

 

 

@ 23

°

 

 

 

 

 

 

 

 

 

Temperature (air) 

 

-20 to 50

o

C (-4.0 to 

122.0

o

F) 

 

±1

o

C (±1.8

o

F) 

Temperature 
(external K) 

 

-200 to 1370

o

C (-328 to 

2498

o

F) 

 

±(0.3% rdg + 1

o

(1.8

o

F)) 

Display 

Triple LCD 

 

Sensor Type 

Humidity: Precision 
capacitance sensor 

 

 

Internal Temperature: 
Thermistor 

 

 

External Temperature: K-Type Thermocouple 

Response Time 

60 seconds typical 

 

Dew Point 

-68 to 50

o

C (-90.4 to 122.0

o

F) (calculated from RH 

and Air temperature 

 

measurements) 

 

Wet Bulb 

-21.6 to 50

o

C (-6.88 to 122.0

o

F) (calculated from 

RH and Air 

 

temperature measurements) 

 

Low Battery 
Indicator 

Yes 

 

Overrange 
Indicator 

E2 (air) E5 (T1), E8 (T2) 

 

Underrange 
Indicator 

E3 (air), E6 (T1), E9 (T2) 

 

Operating 
Conditions 

-20 to 50

o

C (-4 to 122

o

F); < 99% RH non-

condensing 

Storage 
Conditions 

-40 to 85

o

C (-40 to 185

o

F); <99% RH non-

condensing 

Power Supply 

4 x 1.5V ‘AAA’ batteries 

 

Battery Life 

Approx. 300 hours 

 

Dimensions / 
Weight 

230 x 57 x 44mm (9 x 2.2 x 1.7”); 153g (5.3 oz.) 

 

Содержание RHT37

Страница 1: ...ys humidity dew point wet bulb temperature and temperature differential The triple backlit LCD can be changed to display humidity temperature dew point or humidity temperature and wet bulb or humidity...

Страница 2: ...Dew Point Wet Bulb 9 Store Current Reading Backlight 10 Hold Recall Mode 11 RS232 port Note Battery compartment is located on the rear of the instrument Display Description 1 Air T1 Air T1 Dew Point L...

Страница 3: ...in the lower left display 6 Pressing the T1T DPSEL button toggles the top left display between Air temperature T1 temperature Air T1 and DP Dew Point 7 Pressing the T2 WB button toggles the lower lef...

Страница 4: ...re readings in memory Press the Min AVRST button again and MX appears on the display The display is now showing the maximum humidity and temperature readings in memory Press the Min AVRST button again...

Страница 5: ...xt to the memory location number on the display 6 Press the MEM button to manually increment through the stored readings 7 Press RECHOLD MEM for more than 1 second to clear the memory 8 Press RECHOLD...

Страница 6: ...onse Time 60 seconds typical Dew Point 68 to 50o C 90 4 to 122 0o F calculated from RH and Air temperature measurements Wet Bulb 21 6 to 50o C 6 88 to 122 0o F calculated from RH and Air temperature m...

Страница 7: ...e batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated collection poi...

Отзывы: