This CO

2

 meter is designed as wall mount & desktop use. It is powered up by 5VDC through USB-C cable. For 

mobility, you may also use power bank for temporary use. Once CO

2

 is powered, the LED will auto turn on. 

 
 

Prepare an 5V 

Power up the 

Power up the 

USB adaptor 

meter through 

meter through 

 

(

 Not included in package) 

 

USB type-C 

 

USB type-C 

 

 

 

 

 

 
 

CAUTION 

  

Please take off the AC power adapter and store it well when this CO

2

 monitor left idle for long. Please use a 

standard USB power supply (such as PC's USB port, universal AC adapter with USB port). Improper power 
supply can cause serious damage to the device, or result in injury or death to the user. 

 

The vents allow the air circulation liquid for measurement of the CO

2

 concentration and the ventilation 

should not be blocked. 

 

Содержание GSM250

Страница 1: ...erature Wall mount display with light bar to provide easy reading from far distance Touch panel to program the setting NDIR non dispersive infrared waveguide CO2 technology 3 color light bar green yellow red gradually changes color with CO2 concentration CO2 Automatic background calibration called ABC for long time drift compensation Buzzer Alarm function Areas of application Widely used in the of...

Страница 2: ...through Not included in package USB type C USB type C CAUTION Please take off the AC power adapter and store it well when this CO2 monitor left idle for long Please use a standard USB power supply such as PC s USB port universal AC adapter with USB port Improper power supply can cause serious damage to the device or result in injury or death to the user The vents allow the air circulation liquid f...

Страница 3: ...2 50ppm 5 of reading 0 2000ppm Other range is 10 of reading Temperature 0 6oC 0 9oF 5 RH at 25o C 10 90 RH Humidity 7 RH at 25oC other range Response time CO2 30 seconds 63 step change Tair 20 mins 90 step change Humidity 20 minutes 90 step change Operating 14 140 F 10 60oC 0 95 RH avoid condensation o Power supply 5VDC USB type C port Power consumption 500mA Meter size 8 9 x 6 0 x 1 8 226 x 152 x...

Страница 4: ...t Buzzer ABC auto background calibration and bL Brightness of light bar Press key to adjust the parameters Note During the setting process the device will return to the main screen after 25 sec of idle time 4 1 Alarm AL The default alarm setting is 1 000ppm It is adjustable from 800ppm to 3 000ppm the interval is 100ppm This threshold is related to buzzer alarm trigger and red light bar trigger Pr...

Страница 5: ...g is under the lower limit For CO2 E02 Re calibrate For other E02 leave the meter in room condition for 30 mins If it not works send back to repair E03 Measured reading is above the upper limit For CO2 E03 put the meter in fresh air for 5 mins For other E03 leave the meter in room condition for 30 mins If it not works send back to repair E17 ABC mode of CO2 sensor is fail Send back to repair E31 3...