Short press the power button. The buzzer will beep twice and the red 
indicator light on the panel will light up, indicating that the detector is 
on  and  ready  for  use.  The  default  AC  voltage  detection  range  is  90-
1000V. 

  
2. Turning on/off the flashlight 

Flashlight on/off: Short press the flashlight button to turn on/off the 
flashlight. 
The flashlight will automatically turn off when the detector is not used 
for 5 minutes. 

 
3. AC voltage detection 

Place the sensor head near the test object or the power socket with AC 
voltage. When AC voltage is detected, the red LED in the tip and audible 
buzzer will be on. LED frequencies increase when detector gets closer 
to the test object. 

 

Note:  Please  unplug  other  electrical  devices  on  the  socket  before 
detection.  

 
 
 
 
 

Содержание ET350

Страница 1: ...After reading this manual it is recommended to keep the manual at an easily accessible place preferably close to the device for future reference The ET350 is a non contact voltage and magnetic field...

Страница 2: ...fully understand the warnings and operating instructions before use 2 Please test the detector on a known live source within the rated AC voltage range before use 3 If the detector appears damaged or...

Страница 3: ...13 The detector will not detect any voltage if The wire is shielded The operator is not connected with the ground or isolated from an effective ground The voltage is DC 14 The detector may not detect...

Страница 4: ...ity of electric shock Warning Refer to the manual In compliance with the directive of European Union Panel Description Operating Instructions 1 Turning on the detector 1 NCV sensor head 2 Flashlight l...

Страница 5: ...ress the flashlight button to turn on off the flashlight The flashlight will automatically turn off when the detector is not used for 5 minutes 3 AC voltage detection Place the sensor head near the te...

Страница 6: ...eak electrical field environment c Short press the power button once again The green indicator light will switch to yellow and the device will switch to magnetic field detection mode Note In the magne...

Страница 7: ...that the solenoid valve is working properly Note If the magnetic flux is less than 5mT please use the front of the detector tip to detect 6 Auto power off The detector will auto power off when it is n...

Страница 8: ...en indicator Frequency range 50Hz 60Hz Alarm mode Audio visual Flashlight White spotlight Auto power off About 5 minutes Low battery indication Vibration function N A Magnetic field detection mode Yel...

Страница 9: ...to the original purchaser of these goods for use Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of...

Отзывы: