8. Do not assume neutral or ground wire is safe to touch. Incorrect or
poorly connected circuits may cause wires to be charged.
9. The magnetic field generated by magnetized components may
interfere with detection
10. When low battery indication appears, please replace the
batteries.
11. When using the detector, please only hold up to the line before
the translucent sensing part and not over.
12. Comply with local and national safety regulations and
requirements.
13. The detector will not detect any voltage if:
The wire is shielded
The operator is not connected with the ground or isolated
from an effective ground
The voltage is DC
14. The detector may not detect any voltage if:
The operator does not hold the detector
The operator is wearing gloves
The wire under test is partially buried or in a grounded metal
conduit
The magnetic field generated by the voltage source is blocked,
suppressed or interfered with
The frequency of the voltage being detected is not a perfect
sine wave and may be distorted by harmonics
The detector is used outside of the operating specifications
(see Technical Specifications for details)