Page 29
‘Brightness’ can be varied from -128 to +127. A typical setting is +0.
‘Contrast’ can be varied from -128 to +127. A typical setting is +40.
‘Saturation’ can be varied from -128 to +127. A typical setting is +40.
Use the button to select the ‘Video Setting’ mode. Adjust the video settings
using the and buttons to select the desired parameter and
set its value.
MODE
The CamView PTZ automatically determines if the level is ‘Weak’, ‘Normal’ or
too strong (‘Exceed’) and displays a message below the level reading. Weak
is displayed when the signal is 20% low, and Exceed is displayed when the
signal is 20% too high.
112 IRE (0.8 Volts) and below = Weak
140 IRE (1.0 Volts) = Normal
168 IRE (1.2 Volts) = Exceed