Triplett 9325 Скачать руководство пользователя страница 7

Operation

NOTICES

:  Read  and  understand  all  warning  and  precaution 

statements  listed  in  the  safety  section  of  this  operation  manual 
prior  to  using  this  meter.  Set  the  function  select  switch  to  the 
OFF  position  when  the  meter  is  not  in  use.

AC/DC  Current  Measurements 
WARNING:  Ensure  that  the  test  leads  are  disconnected  from 
the  meter  before  making  current  clamp  measurements.

1.Set  the  Function  switch 
to  the  1000ADC,600ADC,
1000AAC  or600AAC  range.

2.If  the  range  of  the 
measured  is  not  known, 
select  the  higher  range  first 
then  move  to  the  lower 
range  if  necessary.

3.Press  the  trigger  to  open 
jaw.  Fully  enclose  one 
conductorto  be  measured.

The  clamp  meter  LCD  will  display  the  reading.

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание 9325

Страница 1: ...Model 9325 True RMS AC DC Clamp On Meter Instruction Manual TRIPLETT 84 898 7 11 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 2: ...g volts do not switch to current resistance modes When changing ranges using the selector switch always disconnect the test leads from the circuit under test Do not exceed the maximum rated input limits CAUTIONS Improper use of this meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always remove the test leads before replacing the battery ...

Страница 3: ...ified by the manufacturer the protection provided by the equipment may be impaired Meter Description 1 Current clamp 2 Non contact AC voltage indicator light 3 Clamp trigger 4 Data Hold and Backlight button 5 Rotary Function swith 6 Hz Hlod button 7 RANGE select button 8 Relative button 9 MIN MAX Hlod button 10 MODE select button 11 LCD display 12 COM input jack 13 V ΩCAP TEMPHz jack 14 Battery Co...

Страница 4: ... and DC direct currrent Minus sign 6000 count 0 to 5999 measurement reading with 61segments Analog Bargraph AutoRange mode Relative mode Diode test mode Audible Continuity Data Hold mode Units of measure list MAX MIN mode Frequency duty cycle mode www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 5: ...0 VAC 600 0 Ω 6 000KΩ 60 00KΩ 600 0KΩ 6 000MΩ 60 00MΩ 40 00nF 400 0nF 4 000μF 40 00μF 400 0μF 4000μF 10 10kHz 20 0 C to 760 0 C 4 0 F to1400 0 F Accuracy of reading 2 8 8 digits 3 0 8 digits 5 0 10 digits 5 0 10 digits 2 8 5 digits 3 0 5 digits 0 8 2 digits 1 5 2 digits 1 8 8 digits 1 0 4 digits 1 5 2 digits 2 5 3 digits 3 5 5 digits Unspecified 3 reading 5 digits 4 0 reading 10 digits 5 0 reading...

Страница 6: ...urrent 0 5mA is displayed OL is displayed 2 per second nominal 10MΩ VDC and VAC 6000 counts LCD 50 400Hz AAC 50 400Hz VAC 41 F to 104 F 5 C to 40 C 4 F to 140 F 20 C to 60 C Max 80 up to 87 F 31 C decreasing linearly to 50 at 104 F 40 C 80 7000ft 2000meters maximum Category III 600V One 9V Battery approx 15 minutes 232x77x39mm 271g For indoor use and in accordance with Overvoltage Category II Poll...

Страница 7: ...hat the test leads are disconnected from the meter before making current clamp measurements 1 Set the Function switch to the 1000ADC 600ADC 1000AAC or600AAC range 2 If the range of the measured is not known select the higher range first then move to the lower range if necessary 3 Press the trigger to open jaw Fully enclose one conductorto be measured The clamp meter LCD will display the reading ww...

Страница 8: ...evice under test so the rest of the circuit will not interfere with the resistance reading 4 For Resistance tests read the resistance on the LCD display Diode and Continuity Measurements 1 Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive diode jack 2 Turn the rotary switch to the CAP position 3 Press the MODE button until appears...

Страница 9: ...black lead banana plug into the negative COM jack and the red test lead banana plug into the positive Hz jack 5 Touch the test probe tips to the circuit under test 6 Read the frequency on the display 7 Press the Hz button again to indicate on the display Read the of duty cycle on the display Temperature Measurements WARNING To avoid electric shock disconnect both test probes from any source of vol...

Страница 10: ...roximity to the live conductor NOTE The detector is designed with high sensitivity Static electricity or other sources of energy may randomly trip the sensor MODE BUTTON To select DC ACV OHM Diode Continuity CAP C F MIN MAX Recording Button Press MIN MAX to enter MIN MAX Recording mode manual range only Select the proper range before selecting MIN MAX to ensure that the MIN MAX reading will not ex...

Страница 11: ...icator will turn on 2 Press the RANGE button to step through the available ranges until you select the range you want 3 Press and hold the RANGE button for 2 seconds to exit the ManualRanging mode and return to AutoRanging Backlight Button The backlight function illuminates the display and is used when the ambient light to too low to permit viewing of the displayed readings Press the button for tw...

Страница 12: ...ruments and test equipment Our obligation under this warranty is limited to repair ing replacing or making refund on any instrument or test equipment which proves to be defective within three years from the date of original purchase This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way so as in our sole judgment to injure their s...

Страница 13: ...onsequential damages Some states USA ONLY do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you No representative of Triplett Jewell Instruments or any other person is authorized to extend the liability of Triplett in connection with the sale of its products beyond the terms hereof Triplett reserves the right to di...

Отзывы: