MAX, MIN, AVERAGE and MAX‐MIN

 

 

In the MAX MIN AVG mode the  meter will record the Maximum  value 
scanned,  Minimum  value  scanned,  the  Average  of  the  scanned  values 
and the Difference between the Max and Min value. 

  

1.

 

Turn Max Min ON in the settings mode 

 

2.  Press and hold the trigger to scan an area. Max, 

Min,  Avg  or  Max‐Min  will  be  displayed  in  the 

lower right display. Press the up 

 button to 

 

select the parameter to be displayed. The 
values will be continuously updated for the 
length of the scan. 
 

 

UV Leak Detector 

 

Inject a small amount of florescent dye into the system under test. 
The dye/system mixture (refrigerant, for example) will escape and 
accumulate at all leak sites. Turn the blue UV LEDs on in the Setting 
mode and scan the system. The residue of the dye at the leak can be 
easily observed under the UV light. Dyes are available at most HVAC 
supply outlets. 

 

Locating Hot or Cold Spots 

  

To  detect  a  hot  or  cold  spot,  aim  the 
thermometer  at  a  region  beyond  the  target 
and  then  scan  the  entire  region  in  a  slow, 
up/down motion. 

 
 
 
 
 
 

Содержание 614395004392

Страница 1: ...User Manual IRTUV50 IR Thermometer with Built in UV Refrigerant Leak Detector and Flashlight...

Страница 2: ...eatures Measures non contact surface temperature up to 932 F 500 C 12 1 Distance to Spot Ratio Field of View Precise non contact measurements Multipoint laser sighting White LED built in illuminators...

Страница 3: ...only as described in this User Guide Cautions To avoid thermometer damage please avoid the following hazards EMF from welding equipment or electro induction heaters o Static electricity Thermal shock...

Страница 4: ...Scan Icon 2 DATA HOLD 3 Laser ON Indicator 4 UV LED ON Indicator 5 HI and Low Alarm 6 Measurement Data 7 Work Light LED ON 8 C F Icon 9 MAX MIN AVG DIF Mode Indicator 10 Emissivity 11 APO Auto Power...

Страница 5: ...ated below the display The available parameters are listed below Setting Mode Overview The Settings switch has five positions to select a parameter turn a parameter ON or OFF and to adjust parameter v...

Страница 6: ...ter the Setting mode Advance until the UV icon flashes Press up for ON or OFF Press to store the setting 3 Temperature Units Setting Enter the Setting mode Advance until the F or C icon flashes Press...

Страница 7: ...e until the Alarm LO icon flashes Press up or down for ON or OFF Press to store the setting If ON was selected Press up or down to adjust the limit Press to store the setting 9 Backlight Setting Enter...

Страница 8: ...ll light if the batteries are good Replace the batteries if the display does not light 5 Release the Trigger the reading will HOLD for the time set in the APO setting The backlight will turn off after...

Страница 9: ...displayed The values will be continuously updated for the length of the scan UV Leak Detector Inject a small amount of florescent dye into the system under test The dye system mixture refrigerant for...

Страница 10: ...be so large that it encompasses surface areas not intended to be measured Emissivity Emissivity represents the energy reflectivity of a material Most organic materials and painted or oxidized surfaces...

Страница 11: ...reading Repeatability of reading 8 of reading or 1 0 C 1 8 F whichever is greater Emissivity Adjustable from 0 10 to 1 00 Temp Coefficient 0 1 C C or 0 1 C of reading whichever is greater Field of Vie...

Страница 12: ...61010 1 Warranty Triplett Jewell Instruments extends the following warranty to the original purchaser of these goods for use Triplett warrants to the original purchaser for use that the products sold...

Отзывы: