ENGLISH
INSTRUCTIONS FOR USE
20
Jaguar 26R - 9100001306
04/2015
Solution/clean water tank emptying
7. Perform steps 1 to 3.
8. Remove the adapter (28) from its housing inside the battery compartment.
9. Install the adapter (A, Fig. 4) on the squeegee vacuum hose (B), then fasten it to the drain valve (C).
10. Turn the ignition key (58) to “I” and turn on the vacuum system with the switch (63).
11. Open the drain valve (C) to drain the tank (22).
The valve (C) is open when it is in the position (D) and it is closed when it is in the position (E).
12. Then, turn of the vacuum system and drain the recovery tank (19) with the hose (24).
13. When the procedure is over, close the drain valve (C), remove the adapter (A) and install the vacuum hose (B) on the
squeegee (30).
A
B
C
E
D
C
Figure 4
P100366
AFTER USING THE MACHINE
After working, before leaving the machine:
1. Remove the brushes/pad-holders as shown in the relevant paragraph.
2. Empty the tanks (19 and 22) as shown in the previous paragraph.
3. Remove the squeegee (30) and clean it with hot water. Open the recovery tank cover (20) and hang the squeegee on the
recovery tank by using the relevant hook (15).
4. Perform the daily maintenance procedures (see the Maintenance chapter).
5. Store the machine in a clean and dry place, with the brushes/pad-holders and the squeegee lifted or removed.
PUSHING/TOWING THE MACHINE
To push/tow the machine easily when the drive system cannot be used (for example in case of missing batteries, discharged
batteries, etc.), disengage the electromagnetic brake by pulling the lever (7) and locking it with a spacer.
When the operation is over, remove the spacer under the lever (7) to activate the electromagnetic brake again.
WARNING!
If the lever (7) is not disengaged after pushing/towing the machine, the electromagnetic brake is disengaged.
WARNING!
Do not start the machine when the electromagnetic brake is disengaged.
For safety reasons, it is recommended to disengage the electromagnetic brake only for the time necessary to
manually move the machine.
MACHINE LONG INACTIVITY
1. If the machine is not going to be used for more than 30 days, proceed as follows:
2. Perform the procedures shown in After using the machine paragraph.
3. Before disconnecting the battery red connector (9), proceed as follows:
• Open the cover (20) and the plug (23), then check that the tanks (19 and 22) are empty, otherwise empty them.
• Keep the recovery tank assembly (19) lifted by using the stand (25).