INTRODUCTION
The
SSS Achiever 40
is a fully self-contained, portable carpet extractor system.
The Achiever 40 has a 60 psi solution pump and a two (2) jet spraying system to apply solution to the carpet.
A rotating brush is driven by a cogged belt system at approximately 1000 RPM’s. This brush provides a very aggressive agita-
tion of the solution into the carpet fibers to loosen ground-in dirt. The chevron pattern of the brush bristles channels the dirty
water to the center of the 12” aluminum vacuum head for better extraction.
The two-stage vacuum motor on the Achiever 40 is capable of 80 inches of water lift. The Achiever 40 extracts virtually all of
the dirty solution from the carpet fibers, which dramatically reduces drying time.
The Achiever 40 is a very “user friendly” machine. All controls are located at the top of the handle grips, literally at your
fingertips. The Achiever 40 has a 4 gallon solution tank and a 3 gallon lift out recovery tank.
This machine must be grounded. If it should malfunction or break down,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This machine is equipped with a cord having an
equipment-grounding conductor and grounding plug. The plug must be
inserted into an appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
WARNING
- Improper connection of the equipment-grounding conductor
can result in a risk of electric shock. Check with a qualified electrician
or service person if you are in doubt as to whether the outlet is properly
grounded. Do not modify the plug provided with the machine - if it will not
fit the outlet, have a proper outlet installed by a qualified electrician.
This machine is for use on a nominal 120-volt circuit, and has a grounded
plug that looks like the plug illustrated in figure A. A temporary adapter
that looks like the adapter illustrated in figures B and C may be used to
connect this plug to a 2-pole receptacle as shown in figure B if a properly
grounded outlet is not available. The temporary adapter should be used only
until a properly grounded outlet (figure A) can be installed by a qualified
electrician. The green colored rigid ear, lug, or the like extending from
the adapter must be connected to a permanent ground such as a properly
grounded outlet box cover. Whenever the adapter is used, it must be held
in place by a metal screw.
NOTE: In Canada, the use of a temporary adapter is not permitted by the
Canadian Electrical Code
EXTENSION CORDS
Use only three-wire 14/3 or larger gauge approved extension cords that have
three-prong grounding type plugs and three-pole receptacles that accept the
appliance’s plug. Replace or repair any damaged cords or plugs.
When servicing, refer to authorized person only. Use only identical
replacement parts.
Grounding Instructions
NOTE:
Do not use adapters shown in figures B & C in Canada