that box which will halt the updates such that the browser page must be refreshed in order to get
an update. Under most conditions, the Continuous Update box should remain checked.
Continuous Update
box should remain
checked in most cases
Figure 8.1.1-7 - Continuous Update Box Should Remain Checked Under Most Conditions
8.2
System Status
Clicking on the
System Status
area of the menu bar provides specific module information such as
the part number, model number, and serial number, see Figure 8.2-1. Additionally, a Module Fault
Status indication is shown. The Module Fault Status indication is shown in this window as well as in
the LED located on the top side of the module. The Module Fault Status is a logical OR of several
alarms which are laser bias current exceeds the maximum current limit, laser pump temperature
out of valid operating range, laser driver current limit reached, and laser driver junction
temperature limit reached. If any of these conditions occur, the Module Fault Status indication will
alarm (Red). These four conditions indicate a problem with the laser and will cause an automatic
laser shutdown (ALS). To clear an ALS condition, the user must click the Reset Fault button which is
located on the bottom row of the Control Functions as shown in Figure 8.2-2. If the fault condition
will not clear, please contact us (TPC) since a hardware failure may have occurred.
Figure 8.2-1 - System Status Information