IX. TROUBLESHOOTING
All TRION Air Cleaners are manufactured to give the user continued, trouble-free service. However, as with all mechanical
equipment, breakdowns can occur.
Refer to the “Replacement Parts Ordering Information,” Figures 5 & 6, for replacement parts.
Before troubleshooting the unit, review the safety information on page 3, refer to the Wiring Diagram, check for proper wiring
connections, and the correct input line voltage.
TROUBLESHOOTING PROCEDURE
TURN UNIT ON
MOTOR OPERATES
PROPERLY. SUPPLY
VOLTAGE PRESENT AT
UNIT.
MOTOR DOES NOT
OPERATE. SUPPLY
VOLT AGE PRESENT
AT UNIT.
MOTOR OPERATES
INTERMITTENTLY.
SUPPLY VOLTAGE
PRESENT AT UNIT.
MOTOR OPERATES
WITH LITTLE OR NO
AIR VOLUME FROM
THE UNIT.
NO
YES
NO
CHECK FOR:
1. FAULTY CONTROL
SWITCH
2. MOTOR TURNS
FREELY
3.FAULTYMOTOR
CAPACITOR‐IF USED
4.FAULTYMOTOR
5. WIRE
DISCONNECTED
CHECK FOR:
1. AIR PASSING BY
FILTERS
2. HOLES IN FILTERS
3. DIRT IN MOTOR
CAUSING
OVERHEATING
4. IMPROPER WIRING
5. MAIN FILTER
MISSING
6. ACCESS DOOR NOT
CLOSED COMPLETELY
CHECK FOR:
1. DIRTY OF CLOGGED
FILTERS
2. REGISTER LOUVERS
BLOCKED
3. BLOWER WHEEL
BLADES DIRTY
4. BLOWER WHEEL
LOOSE
5. INCORRECT LINE
VOLTAGE
NO
YES
YES
REPAIR
COMPLETED
UNIT OPERATES
PROPERLY
MOTOR OPERATES
PROPERLY
CONTACT YOUR LOCAL
TRION DISTRIBUTOR
NO
YES
YES