www.trioniaq.com
T-Series
6
I n s t a l l a t i o n , O p e r a t i o n , a n d S e r v i c e M a n u a l
Cleaning
To maintain optimum collection efficiency, the pre-
filters and ionizer/collector cells should be removed
periodically and soaked in a solution of hot water
and TRION Tridex detergent for 2 to 4 hours, rinsed
thoroughly and then air dried completely before
reinstalling in the unit.
The frequency of cleaning is dependent on the type of
contaminant being collected. Liquid aerosol requires
less cleaning while welding smoke may require more
frequent cleaning.
Wash Ionizing/Collecting Cells
NOTE
TRION Tridex Detergent is specially formulated
for use with TRION electronic air cleaners.
Use of other cleaners and detergents, not
specifically approved by TRION, can cause
possible failures in the unit and will void any
and all warranties on our equipment.
WARNING
DO NOT USE HIGH PRESSURE STEAM
CLEANING EQUIPMENT TO CLEAN CELLS.
THE EXCESSIVE HEAT AND PRESSURE WILL
CAUSE THE PLATES TO WARP AND IN TURN
POSSIBLY CAUSE EXCESSIVE ARCING.
1. Turn the control switch “OFF” and disconnect
power to the unit.
2. Open the cell access door.
3. Remove ionizer/collector cells and wash in HOT
detergent water.
4.
Remove the mechanical pre-filter. Remove
collected dust or lint by vacuuming or brushing.
Wash with warm, soapy water.
5. Rinse all components thoroughly in warm, clear
water and allow to drip dry completely.
6.
Replace pre-filters and ionizer/collector cells.
ENSURE the airflow arrows point in the direction
of airflow (towards the blower).
7. Close the access door; reconnect power to the unit.
8. Turn control switch to “ON”. If arcing occurs or the
indicating light flickers, the components may still
be damp. Turn the unit OFF and allow the cells to
dry completely.
Inspections
The motors and blowers on TRION T1300 and T2600
air cleaners have sealed ball bearings and never need
lubricating.
Belt tension should be checked periodically. When a
moderate force is applied to the belt midway between
the pulleys, the belt should deflect approximately ½”
(13 mm).
The following pages contain exploded views and
Bills of Material for the TRION T-Series Air Cleaners.
Use these pages to determine the part numbers of
the items needed. To order parts contact your local
TRION representative and provide the following
information:
• Unit Model Number – located on the data label
near the junction box
• Part Number and Description – from exploded views
CAUTION
Having too much tension on the belts will
shorten the belt life and place undue stress on
the motor and blower bearings.
Replacement Parts Ordering