3

ELECTRICAL INFORMATION

SYMBOLS:

 

The lightning flash with arrowhead symbol is to alert the user to
the presence of uninsulated “dangerous voltage” within the
product enclosure that may be of sufficient magnitude to
constitute risk of electric shock to persons. 

 

The warning label is to instruct service personnel to disconnect
the mains supply before removing the front cover. 

 
CAUTION: 

To reduce the risk of fire or electric shock, do not expose this
unit to excessive temperatures, rain or moisture. 

 

Always disconnect this unit from the supply when not in use for
lengthy periods. 

 
IMPORTANT: Servicing should only be done by qualified personnel. No user-

serviceable parts inside. 

 

  MAINS OPERATION: 

 
 

The wires in the lead are coloured in accordance with the
following wiring codes: 

 
  

BROWN…………………LIVE 

  

BLUE…………………….NEUTRAL 

  

YELLOW/GREEN………EARTH 

 

 

 

The wires in the mains lead must be connected to the terminals
in the plug as follows: 

 
 

 

BROWN WIRE…………L OR RED 

  

BLUE 

WIRE……………N 

OR 

BLACK 

 

 

YELLOW/GREEN……..E OR EARTH 

 

 

The plug should be fitted with a 3 amp fuse 

 

 

NOTE: THIS UNIT MUST BE EARTHED. 

 

INTERNAL FUSES:  

 

                         The following fuses are fitted within the equipment: 

 

                                          OZONE GENERATOR 

  

                         220 – 240V-2 No. 1A TYPE (T) – 20mm 

 

110 – 120V-2 No. 2A TYPE (T) – 20mm 

 

                                                AIR DRYER 

 

 

220 – 240V No. 1.6A TYPE (T) – 20mm 

 

110 – 120V No. 3A TYPE (T)    – 20mm 

Содержание CH2-50-1

Страница 1: ...Degr mont Technologies Triogen East Kilbride G75 0YF Scotland Tel 44 0 135 522 0598 Fax 44 0 135 557 0058 English Version April 2011 Compact Ozone System Installation Operating Instructions...

Страница 2: ......

Страница 3: ...ING SYSTEM 8 OZONE GENERATOR MOUNTING DETAIL 9 DRYER MOUNTING DETAIL 9 T2 INSTALLATION DIAGRAM 10 T2 INSTALLATION DIAGRAM CONTACT 10 T4 INSTALLATION DIAGRAM CONTACT 11 T8 INSTALLATION DIAGRAM CONTACT...

Страница 4: ...T kg 29 empty CH2 50 1 TECHNICAL INFORMATION WATER FLOW m3 hr 2 4 PRESSURE m head 28 VOLTAGE v ph hz 110 230 1 50 60 POWER watts 710 WEIGHT kg 12 0 CH4 50 1 TECHNICAL INFORMATION WATER FLOW m3 hr 4 8...

Страница 5: ...from the supply when not in use for lengthy periods IMPORTANT Servicing should only be done by qualified personnel No user serviceable parts inside MAINS OPERATION The wires in the lead are coloured i...

Страница 6: ...frequency power board driving a ceramic corona discharge module which is air cooled by an integral cooling fan Normal atmospheric air can be used as the feed gas or pre dried air supplied by a Trioge...

Страница 7: ...assing system is adopted as entrained air entering the pool can be visually unacceptable and could have a bleaching effect on pool liners or covers 5 The ozone induction system is comprised of an air...

Страница 8: ...tor when the water booster pump is stopped The water trap assembly should be wall mounted as close as possible to the injector at a distance not exceeding 3 metres and at the height indicated After mo...

Страница 9: ...herefore any obstruction of ventilation or excessive heat will cause damage and shorten the life of the equipment If the ozone generator is being installed in an unheated outdoor plantroom for use wit...

Страница 10: ...upplied as a loose item should then be connected to the bottom of the 3 8 pipe ensuring that the flow arrow on the valve is pointing in the direction shown on the installation diagrams The assembly sh...

Страница 11: ...9 AIR DRYER WALL MOUNTING DETAIL OZONE GENERATOR WALL MOUNTING DETAIL...

Страница 12: ...10 T2 INSTALLATION DIAGRAM NO CONTACT DEGASSER T2 INSTALLATION DIAGRAM WITH CONTACT DEGASSER...

Страница 13: ...11 T4 INSTALLATION DIAGRAM WITH CONTACT DEGASSER T8 INSTALLATION DIAGRAM WITH CONTACT DEGASSER...

Страница 14: ...ystem must run on a 24 hour cycle as the head of water created could cause a leak through the vent valve and find its way into the plantroom via the waterpot If the plant has to be closed down for any...

Страница 15: ...13 WATER TRAP ASSEMBLY...

Страница 16: ...rter unit NOTE UNDER NO CIRCUMSTANCES SHOULD THE GENERATOR OR THE AIR DRYER BE HARD WIRED DIRECTLY TO A POWER SUPPLY IF THIS IS DONE THE WARRANTY OF THE UNITS ARE IMMEDIATELY INVALID NOTE UNDER NO CIR...

Страница 17: ...the redox controller reaches the low set point the ozone generator booster pump and solenoid valve on the brominator are energised automatically and continue to run until the redox controller reaches...

Страница 18: ...d re started several times to ensure that the ball check valve incorporated in the water trap assembly seals properly and stops any water backflow from the injector Once this has been checked then the...

Страница 19: ...f 25mm from the top of the pot Check that the correct airflow is being drawn through the ozone generator and adjust if necessary Check that the injector booster pump is operating correctly On systems...

Страница 20: ...NPUT VERSION FAN0001 4 OZONE MODULE END CAP MPP0089 5 MALE ADAPTOR UNION 8mm 1 8 ST ST MPM0072 6 UNION SEAL RING 1 8 FES0034 7 PANEL MOUNTED UNION 8mm x 8mm PVDF PPF0209 8 MODULE THERMOSTAT 70oC EMC01...

Страница 21: ...VALVE 230V ESV0026 4 3 PORT SOLENOID VALVE 110V ESV0027 5 PURGE PUMP 230V MPM0005 6 PURGE PUMP 110V MPM0004 7 HEATER ELEMENT 125 WATT 230V HTR0009 8 HEATER ELEMENT 125 WATT 110V HTR0008 9 HEATER ELEM...

Страница 22: ...riate address and that transportation is prepaid The servicing agent is satisfied that the claimed defects are traceable to the original parts of workmanship The warranty will be deemed void if the eq...

Страница 23: ......

Страница 24: ...Degr mont Technologies Triogen East Kilbride G75 0YF Scotland Tel 44 0 135 522 0598 Fax 44 0 135 557 0058...

Отзывы: