Trio Pro Pilot Manual 4.1
48
Chapter 11
Configuration Menu
The Pro Pilot provides a quick and easy method to set up certain parameters - some that are normally
only changed during installation and some that are commonly accessed in flight. These are divided into
two different menus, the “
Configuration Settings Menu
” and the “
Preferences Settings Menu
”.
The
Configuration Menu
may be accessed by pressing and holding the encoder knob only
while turning on the power to the system. These are settings that normally are set up one time
and need not be addressed again. Some parameters, such as setting servo direction, are not
accessible in flight.
The
Preferences Menu
is accessed by pressing the encoder knob and holding it in for 3
seconds while in the navigation display. These menus contain settings that the pilot can adjust
in flight to optimize the Pro Pilot for current flight conditions.
Using the Configuration Menus
The
Configuration
menu may be accessed in flight in the following manner:
With the power off, press and hold the encoder knob while turning on power to the Pro Pilot.
Once the
CONFIG SETTINGS
screen is observed release the encoder knob.
Paging through the options is accomplished by pressing the encoder knob sequentially to sequence
forward, or by rotating the encoder knob to move to the next or previous display.
Once the appropriate screen has been selected, pressing the
H MODE
button will activate the cursor and
place the triangular arrow on the screen indicating the display values can be adjusted or changed.
Rotating or pressing the encoder will change the screen settings. The screen will not update if the arrow
is not present.
To exit a screen, press the
H MODE
button until the arrow is no longer present on the display. This
makes it possible to again page through the setup screens using the encoder knob..
To exit the
CONFIGURATION SETTINGS
menu, press and hold the encoder knob for a period of 3
seconds and the screen will return to the navigation functions.
Settings Available In the Configuration Menu
MIN AS SET -
Sets the minimum airspeed limit for the autopilot
MAX AS SET -
Sets the maximum airspeed limit for the autopilot
VNAV SERVO SET
- Allows setting of the VNAV servo direction (* not available in flight)
V_TRIM SPEED/DIR
– Allows setting speed and direction of the VNAV trim motor if the auto-trim
option is installed
HNAV SERVO SET
– Allows setting the HNAV zero position and servo direction (* The direction
setting is not available in flight)
AS/VS SELECT –
Sets the airspeed capture (AS) or vertical speed capture (VS) option for PCS
MAX TURN RATE
– Sets the automatic or manual maximum turn rate
CIRCLE LAST WPT?
– Sets the option to circle the last flight plan waypoint or to proceed on
prior course thereafter
SET_DEFAULT VERT RATE
– Allows selection of the default vertical rate
AP DISCONNECT MD –
Allows selection of just the HNAV or VNAV or both on PCS disconnect
action if two yoke/stick PCS buttons are installed. A single button should always be AND (both).