![Trinamic TMCM-351 Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/trinamic/tmcm-351/tmcm-351_firmware-manual_1163054066.webp)
TMCM-351 TMCL Firmware V4.45 Manual (Rev. 1.06 / 2014-MAY-16)
66
www.trinamic.com
4.6.40
TMCL Control Functions
There are several TMCL control functions, but for the user are only 136 and 137 interesting. Other control
functions can be used with axis parameters.
INSTRUCTION NO.
TYPE
COMMAND
DESCRIPTION
136
0 – string
1 – binary
Get firmware
version
Get the module type and firmware revision as a
string or in binary format. (
Motor/Bank
and
Value
are ignored.)
137
don’t care
Reset to factory
defaults
Reset all settings stored in the EEPROM to their
factory defaults
This command does not send back a reply.
Value must be 1234
F
URTHER INFORMATION ABOUT COMMAND
136
-
Type set to 0 - reply as a string:
Byte index
Contents
1
Host Address
2… 9
Version string (8 characters, e.g. 351V.442)
There is no checksum in this reply format!
-
Type set to 1 - version number in binary format:
The version number is output in the
value
field of the reply in the following way:
Byte index in value field
Contents
1
01
2
5F
3
Type number, low byte
4
Type number, high byte