TMCM-351 TMCL Firmware V4.45 Manual (Rev. 1.06 / 2014-MAY-16)
26
www.trinamic.com
Example:
Move motor 0 to previously stored coordinate #8
Mnemonic:
MVP COORD, 0, 8
Binary:
Byte Index
0
1
2
3
4
5
6
7
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Value (hex)
$01
$04
$02
$00
$00
$00
$00
$08