background image

天合光能

TS4

连接器安装手册

 

Trina Solar TS4 Connector Installation Manual

 

 

14 

Spanner

 

7A001039

数量

Qty.

 

7A001037 

数量

Qty.

 

7A001038

数量

Qty.

 

7A001036

数量

Qty.

 

7A004541

Qty.

 

7A004675 

1pc 

None 

1pc 

None 

2pcs 

 

5.2 

组装步骤

  Assembly Steps 

组装连接器时,环境温度建议为

-

15~+35℃

For assembling of components we recommend 

an ambient temperature between -

15~+35℃.

 

5.2.1

 

剥线

  Stripping 

 

剥离线缆塑料绝缘层。

L=6±0.5mm

Strip the plastic insulating layer of cable. L=6±0.5mm. 

注意:不要切断和损坏线缆绝缘塑料下的铜丝线芯。

Note:

  Please  pay  attention  and  do 

NOT cut off and damage the copper wire core under the cable insulating plastic. 

5.2.2

 

放入插针插套

  Inserting pin and socket 

           

           

 

7A001038                                                              7A001036

 

将金属端子(插针或插套)放在铆接工具孔内,铆接孔朝外,使金属端子的最外侧边缘

Содержание TS4-F1

Страница 1: ...TS4 Trina Solar TS4 Connector Installation Manual 1 File No PS M 0779 Version F Date 2021 10 12...

Страница 2: ...8 4 Connector Appearance Size Drawing 9 4 1 TS4 TS4 PV connector 9 4 1 1 Positive Connector 9 4 1 2 Negative Connector 10 4 2 TS4 Plus TS4 Plus PV connector 11 4 2 1 Positive Connector 11 4 2 2 Negat...

Страница 3: ...Installation Manual 3 5 2 4 Pushing 17 5 2 5 Install the nut 17 6 Connecting and Disconnecting 19 6 1 Connecting 19 6 2 Disconnecting 19 7 Cable 19 7 1 Connection of Cable 19 7 2 Connection Status 20...

Страница 4: ...afety or conformity with the technical data Do not modify the product in any way 1 1 2 Connector must be mated with connector qualified by Trina Solar otherwise Trina Solar will disclaim any warranty...

Страница 5: ...Unmated plug connectors must protected from moisture and dirt with a sealing cap If soiled the male and female connectors must not be plugged together 1 3 3 IP68 The plug connectors are watertight in...

Страница 6: ...30 60 70 We recommend TS4 connector storage and transportation temperature between be 30 and 60 and a relative humidity of less than 70 Storage and transportation at normal temperature must avoid dir...

Страница 7: ...85 41A 4 0mm2 12AWG 46A 6 0mm2 10AWG 55A 10 0mm2 8AWG Rated impulse voltage 16KV Ambient temperature range 40 85 Contact resistance 0 5m Application degree Class A Protection class Class Pollution de...

Страница 8: ...4 F4 7A000984 6 0 7 2 TS4 M4 7A000985 TS4 F5 7A000992 7 2 8 7 7A001036 TS4 M5 7A000981 TS4 F6 7A000990 10 0 8 7A001037 TS4 M6 7A000991 TS4 F7 7A004375 6 6 7 2 4 0 6 0 12 10 7A001039 7A001036 TS4 M7 7A...

Страница 9: ...the cable and ensure that the cross sectional area of the conductor and the OD of the cable are within the range Otherwise it will affect the use and create safety risks 2 O Note 2 The specification...

Страница 10: ...TS4 Trina Solar TS4 Connector Installation Manual 10 4 1 2 Negative Connector TS4 M1 TS4 M2 TS4 M3 TS4 M4 TS4 M9 TS4 M5 TS4 M6 TS4 M7 TS4 M8...

Страница 11: ...Manual 11 4 2 TS4 Plus TS4 Plus PV connector 4 2 1 Positive Connector TS4 Plus F1 TS4 Plus F2 TS4 Plus F3 4 2 2 Negative Connector TS4 Plus M1 TS4 Plus M2 TS4 Plus M3 5 Installation 5 1 Tools Require...

Страница 12: ...12 7A001039 7A001037 P N Jaw Crimping Range 7A001039 Middle 4 0mm2 12AWG Right side 6 0mm2 10AWG 7A001037 Right side 10 0mm2 8AWG 5 1 2 Rivet Plier 7A001038 7A001036 P N Jaw Riveting Range Picture 7A...

Страница 13: ...N 7A001040 TS4 Plus P N 7A004541 5 1 4 Tool Box TS4 For TS4 Connector P N Wire Stripper Rivet Plier TS4 Unlocking Spanner Picture 7A001039 Qty 7A001037 Qty 7A001038 Qty 7A001036 Qty 7A001040 Qty 7A001...

Страница 14: ...e 2pcs 5 2 Assembly Steps 15 35 For assembling of components we recommend an ambient temperature between 15 35 5 2 1 Stripping L 6 0 5mm Strip the plastic insulating layer of cable L 6 0 5mm Note Plea...

Страница 15: ...metal terminal and make sure all the individual strands are in the hole Ensure the coaxially of metal parts and cables Finally press the riveting tool handle all the way and press it to the end to co...

Страница 16: ...r Cable spec Connector type 4 4 0mm2 12AWG TS4 F5 F7 F8 TS4 M5 M7 M8 6 6 0mm2 10AWG 8 10 0mm2 8AWG TS4 F6 TS4 M6 IEC62852 Qualified crimping samples must meet IEC 62852 and the following criteria The...

Страница 17: ...ull the cable to check whether the metal terminals are firmly engaged Confirm that the negative pin is coaxial with the negative body Note Before inserting the cable and metal terminal into the plasti...

Страница 18: ...M7 6 6 7 2mm 0 X 1 0mm 3 0 5 N m TS4 F8 M8 5 6 6 6mm 0 X 1 0mm TS4 F9 M9 6 9 7 5mm 0 X 1 0mm TS4 Plus For TS4 Plus Connector Type Cable OD range Control gap Reference torque TS4 Plus F1 M1 4 7 6 0mm...

Страница 19: ...rol value On the contrary it is biased to the upper limit of the control value 6 Connecting and Disconnecting 6 1 Connecting Plug the coupling together until they engage And pull lightly to check corr...

Страница 20: ...elow Note Please refer to the detailed instructions on the minimum bend radius specified by the cable manufacturer 7 2 Connection Status 8 Trina Solar Service Point Trina Solar Co Ltd 2 ADD No 2 Tian...

Страница 21: ...133 59 39 USA Canada 100 Century Center Suite 501 San Jose CA 95112 1 800 696 7114 NAservice trinasolar com Japan 21F World Trade Center Building 2 4 1 Hamamatsu cho Minatu ku Tokyo 106 6121 81 3 3437...

Отзывы: