Installation and Safety Manual

Trinasmart

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

•  This manual contains important instructions for the installation and maintenance of the Trinasmart 

Optimizer System Integrated PV Module and J-Box

•  Risk of Electric Shock, Do Not Remove Cover. No user serviceable parts inside. Refer servicing to 

qualified service personnel.

•  Before installing or using the Trinasmart Optimizer System, please read all instructions and warning 

markings on the Trina Solar products, appropriate sections of your inverter manual, photovoltaic (PV) 

module installation manual, and other available safety guides.

•  Failure to adhere to these instructions may result in injury or death, damage to the system, and 

voiding the factory warranty.

•  To reduce risk of fire and shock hazard, install this device with strict adherence to National Electric 

Code (NEC) ANSI/NFPA 70 and/or local Electrical Codes. When the photovoltaic array is exposed to 

light, it supplies a DC voltage to the Trinasmart Module Optimizer. The Trinasmart Optimizer will start 

in the “on” state and its output voltage may be as high as the PV module open circuit voltage (Voc) 

when connected to the module. The installer should use the same caution when handling electrical 

cables from a PV module with or without the Trinasmart Optimizer attached.

•  Installation must be performed by trained professionals only. Trina Solar does not assume liability for 

loss or damage resulting from improper handling, installation, or misuse of products.

•  To avoid risk of electrical shock or fire, do not attempt to disassemble or repair the product. 

•  Remove all metallic jewelry prior to installing the Trinasmart Module Optimizer to reduce the risk of 

contacting live circuitry. Do not attempt to install in inclement weather.

•  Do not operate the Trinasmart Module Optimizer if it has been physically damaged. Check existing 

cables and connectors, ensuring they are in good condition and appropriate in rating. Do not 

operate the Trinasmart Module Optimizers with damaged or substandard wiring or connectors. The 

Trinasmart Module Optimizer should be mounted at a minimum of 3 feet above ground.

•  Do not connect or disconnect under load. Authorized service personnel should reduce the risk of 

electrical shock by pressing the Trinasmart PV-Safe button on the Trinasmart  Management Unit 

and disconnecting the AC and DC power from the system before attempting any maintenance or 

working on any electrical circuits connected to the Module Optimizers. Turning off the Inverter and/

or the Trinasmart Optimizer may not reduce this risk. Internal capacitors within the inverter can 

remain charged for several minutes after disconnecting all power sources.

Units are shown in SI (English).

Содержание Trinasmart

Страница 1: ...Installation and Safety Manual TSM_Trinasmart_Installation and Safety Manual_2012_RevB...

Страница 2: ...2 Installation and Safety Manual Trinasmart 3simple steps 1 Configure the System Before Going to the Site 2 Install the Management Unit and Gateway 3 Install the Optimizers and verify system...

Страница 3: ...ng the Management Unit and Gateway 15 Verifying the System 17 Troubleshooting 23 Technical Specifications 25 per UL 1741 This symbol is used to indicate WARNING Failure to follow instructions may resu...

Страница 4: ...PV module with or without the Trinasmart Optimizer attached Installation must be performed by trained professionals only Trina Solar does not assume liability for loss or damage resulting from imprope...

Страница 5: ...nal management and performance monitoring In well designed large scale systems Trinasmart Optimizer systems will return up to 8 incremental power output while in residential or commercial systems with...

Страница 6: ...the MMU will display PVSAFE PRESSED and Requesting to indicate the command has been sent to the Optimizers As the Optimizers are responding the MMU display will indicate how many have successfully dis...

Страница 7: ...user ID password information if already established Installation schematic drawing Phillips and slotted screwdrivers MC4 type connectors 1 male 1 female per string Permanent marker or label maker Dete...

Страница 8: ...8 Installation and Safety Manual Trinasmart IDENTIFYING PARTS OF THE TRINASMART OPTIMIZER SYSTEM Trinasmart Module Optimizer MM ES Gateway Management Unit MMU and Gateway cable...

Страница 9: ...the Mac IDs from the Optimizers ready before beginning the configuration process Optimizer codes can be found on the outside of the box this is not recommended if box has been opened All identificati...

Страница 10: ...wisted pair outdoor rated wire of at least 18AWG See Tigo Energy s website for a list of tested cable options Access the MMU communications ports by pressing the latch at the bottom edge of the clear...

Страница 11: ...ight four pin connector in order to wire the outbound RS 485 cable to the next Gateway Only the final Gateway in the series connection should have a termination resistor When finished replace the cove...

Страница 12: ...cuit do not use a separate or dedicated power supply DO NOT INITIATE DISCOVERY AND POWER ON UNTIL ALL OPTIMIZERS HAVE BEEN INSTALLED NOTE To verify if a connection has been made to the network the ins...

Страница 13: ...ub Array 1 Sub Array 2 Sub Array 4 Sub Array 3 Gateway Gateway Terminated Gateway Position the Gateway at the center of the module cluster and attach to the upper left hand corner of a PV module frame...

Страница 14: ...the modules from the Management Unit console Place this label in a visible location on the front surface of the Fuse Combiner Box typically found adjacent to the array in multi string projects AC Disc...

Страница 15: ...modules return to the Management Unit and initiate the Discovery and Power On command which will also power on the Optimizers if they not powered on already Access this from the MMU display by selecti...

Страница 16: ...communicate effectively with the Gateway By paying close attention to these warning messages the installer can locate the most ideal place for the Gateway to be able to communicate effectively with al...

Страница 17: ...andard PV array Refer to the Troubleshooting section for instructions on verifying the system communication is operating properly Please ensure safety precautions are always observed in order to avoid...

Страница 18: ...off 3 Push Data Immediately attempts to make another communication to transfer data to the data center without having to wait the usual 10 minute period between communications Useful for real time deb...

Страница 19: ...ion can be wired with Cat 5 Ethernet wire The data feed leads A and B on the MMU and Gateway terminal blocks must be connected to the same twisted pair See the table for instructions on connecting the...

Страница 20: ...e Gateway This is useful for troubleshooting problems with the system communications See the table below for the meaning of each light pattern Color pattern Gateway Status No color Not powered from MM...

Страница 21: ...ccess the web via HTTPS proxy and server is not cooperating Verify proxy settings on MMU Verify proxy server allows access to https datacenter tigoenergy com Re initiate network test No default GW Mis...

Страница 22: ...ressing ENTER 4 The next entry field will read SUBNET MASK AND AGAIN 000 000 000 000 Use the four keys as before to move and change the number values 5 The next entry field will read DEFAULT GATEWAY A...

Страница 23: ...d if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular in...

Страница 24: ...nt of ISC 0 053 C Input data MMJ ES50 Maximum Power 300W Maximum Input DC Voltage VOC 52V VMP Range 16 48V Maximum Continuous Current IMP 9 5A Maximum Input Current ISC 10A VMP Voltage at maximum powe...

Страница 25: ...ie Street Sydney NSW 2000 t 61 2 8667 3088 f 61 2 8667 3200 e australia trinasolar com United Arab Emirates Trina Solar Middle East Ltd Office 306 Injazat Building Mohamed Bin Zayed City Abu Dhabi P O...

Отзывы: