OpTK Spring Cylinder Rotary Actuators

4

7. Install cover plate and yoke onto transfer

case. The four tapered lug bolts are used
with the yoke and standard hex bolts are
used with the cover plate.

8. Install base slider O-ring into sliding seal

groove machined in the transfer case.

9. Install actuator stem O-ring into the sliding

seal collar. Then slide the collar over the
actuator stem.

10. Place retaining washer over the collar and

install the spiral retaining ring into the
transfer case.

11. Replace the piston O-ring and piston backup

ring onto piston, making certain the piston
backup ring is on top (toward the top of
cylinder) of the piston O-ring.

Note:

200 square-inch actuators use two

piston backup rings. They are placed on
each side of the piston O-ring.

12. Install the piston stem O-ring and piston on to

the actuator stem.

13. Install the spring guide (50, 100, and 200

square-inch actuators only) and actuator
stem locknut onto the actuator stem. Tighten
the actuator stem locknut firmly.

14. Install the cylinder O-ring into transfer case

groove.

Note:

Replace cylinder O-ring if damaged.

15. Install the spring and spring button.

16. Slide cylinder down over piston and transfer

case.

CAUTION:

The cylinder must be

perpendicular with the piston
when sliding it over the piston O-
ring. If this is not done, the O-ring
could be damaged.

17. Reinsert the cylinder retaining ring in the

cylinder by feeding it a little at a time into the
groove. Make sure it is securely fastened.

WARNING:

Ensure that the

cylinder retaining ring is completely
seated in the cylinder groove.

18. Center the hole in the spring button directly

under the adjusting screw hole. Install the
adjusting screw and tighten only enough to
provide an air seal with the gasket.

Do not

overtighten.

19. If actuator is to be used with a positioner,

mount positioner and connect tubing.

CAUTION:

The actuator cover

plate and yoke must be installed
prior to stroking the actuator.

Mounting Rotary Actuators with non-
clamping lever Optimux Valve Bodies

When mounting a rotary actuator to an Optimux
valve body, refer to product instruction manuals
for the OpDx, OpVee, OpExc valves. When
mounting a rotary actuator on other
manufacturers’ valve bodies, refer to the
appropriate literature.

When mounting an actuator with clamping lever
arm, firmly tighten the clamping bolt on the
splined lever arm. 

Adjusting External Stroke Stops

After disassembly and reassembly it may be
necessary to readjust the external stroke stops to
avoid valve leakage. The external stroke stops
should be adjusted while the valve is out of line.
To adjust the external stroke stops, proceed as
follows:

CAUTION:

Actuators with

clamping lever arms must be
attached to a valve or other
mechanical device and the
transfer cover plate must be
installed prior to stroking the
actuator.

Содержание OPTIMUX OpTK

Страница 1: ...lifting point Therefore support must be given to prevent the actuator from rotating Relieve spring compression by removing adjusting screw 3 Contact your shipper immediately in the case of any shipping damage 4 Contact your Optimux representative with any problems INSTALLATION Prior to installation make sure adequate overhead and side clearance for the actuator is provided to allow for proper remo...

Страница 2: ...lem is suspected with the actuator refer to the Disassembly and Reassembly section 1 Examine the actuator for damage caused by corrosive fumes and process splatter 2 Clean actuator and repaint oxidized areas 3 If possible stroke actuator and check for smooth full stroke operation 4 Remove the transfer case cover plate and make sure the positioner linkage and splined lever arm are securely fastened...

Страница 3: ... case cover plate by removing the four bolts 10 Remove the yoke from the transfer case by removing the four lug bolts 11 Remove the pivot pin from the non clamping lever arm by removing a retaining ring 12 The actuator stem can now be easily removed from the transfer case 13 The non clamping lever arm can be removed by first removing the positioner according to the appropriate positioner maintenan...

Страница 4: ...one the O ring could be damaged 17 Reinsert the cylinder retaining ring in the cylinder by feeding it a little at a time into the groove Make sure it is securely fastened WARNING Ensure that the cylinder retaining ring is completely seated in the cylinder groove 18 Center the hole in the spring button directly under the adjusting screw hole Install the adjusting screw and tighten only enough to pr...

Страница 5: ...e on all actuator sizes contact factory if a problem occurs while reversing the actuator action 1 Disconnect the air and relieve spring compression 2 Remove the transfer case cover plate bolts Carefully slide cover plate off the end of the splined lever 3 On older designs with clamping lever arms loosen the linkage bolt 4 Remove bolts connecting transfer case to the yoke 5 On older designs with cl...

Страница 6: ... 274 Spring Button Item No 227 Actuator Stem Locknut Item No 348 Actuator Stem O Ring Item No 275 Sliding Seal Collar Item No 366 Base Slider O Ring Item No 278 Valve Shaft Item No 51 Transfer Case Item No 204 Adjusting Screw Item No 210 Adjusting Screw Gasket Item No 248 Cylinder Retaining Ring Item No 256 Spiral Retaining Ring Item No 368 Retaining Washer Item No 360 Actuator Stem Item No 211 Sp...

Страница 7: ... Spring Button 229 Spring 238 Follower Pin 246 Yoke Bushing 248 Adjusting Screw Gasket 249 Lever Arm 256 Cylinder Retaining Ring 258 Cover Plate Bushing 269 Piston Backup Ring 271 Piston O ring 272 Piston Stem O ring 274 Cylinder O ring 275 Actuator Stem O ring 278 Base Slider O ring 330 Stroke Stop Bolt 336 Yoke Bolt 337 Cover Plate Bolt 347 Stroke Stop Jam Nut 348 Actuator Stem Locknut 357 Purge...

Страница 8: ...ubleshooting OpTK Spring Cylinder Rotary Actuators Failure Probable Cause Corrective Action Optimux customers should be aware that Optimux products might be used in numerous applications under a wide variety of industrial service conditions Although Optimux can and often does provide general guidelines it cannot provide specific data and warnings for all possible applications The purchaser user mu...