9.
SPECIFICATION
9.1
G
ENERAL
Width
482 mm (including rack ears)
19” rack mounting
Height
44 mm (1U)
Depth
433 mm (excluding connectors)
Weight
4kg with no option boards
5kg max. with all option boards
Operating temperature
range
0
°
C to 50
°
C
Storage temperature
range
-20
°
C to 60
°
C
Operating humidity
20% - 90% (non-condensing when operating at 40
°
C)
9.2
EMC
&
S
AFETY
Emissions
EN 55032:2015
FCC CFR 47 Part 15.107 & 15.109 and ICES-003 Issue 6
EN 61000-3-2:2014, EN 61000-3-3:2013
Immunity
EN 55103-2:2009
Safety
IEC 60950-1:2005/A2:2013
NOTE: Immunity is specified to criterion B - the outputs may suffer some degradation during the
disturbance, but will recover on removal of the disturbance source and continue to operate as
intended.
9.3
P
OWER
Power Supplies
The Mentor CX can accommodate two PSU modules providing
the option to support PSU redundancy. PSU modules are load
sharing and hot swappable.
Mains input x 2
100-240VAC, 50/60Hz, auto select
Power consumption
80 W maximum (depending on number of option boards fitted)
Internal Fuse