8
www.trikdis.com
Radio receiver RFH11
2.
Select the program directory [Settings], then [COM port] in the drop-down list [COM Port], and then select the
port to which the module is connected.
Note: specific port to which the device is connected will appear only after the device is properly connected.
Settings in branch Main:
3.
Read the receiver parameters by clicking [Read].
4.
Set [Frequency] and [Transmitter ID] in the program branch Main.
5.
In the [Transmitter ID] drop-down list you can choose according to what transmitter will be identified by receiver:
-
Account ID – programmed Account ID number will identify transmitter.
-
Transmitter SN –unique serial number will identify transmitter.
-
Transmitter SN + Account ID – transmitter will be identified by both (Transmitter SN and Account ID)
numbers.
Note: [Transmitter ID] parameter should be set identically in all radio transmitters.
Settings in branch Filters:
- [Time filter] – time period in which the same message will be
rejected (recommended time is 90 seconds).
- [RF Coding/Subsystem Filter]– double click on the table, select the required radio coding systems (RAS3, RAS2M,
LARS, LARS1, Milcol-D) and mark subsystems allowed for receiving.
- [Account ID filter] – enter ranges (From which – To which) of transmitter Account ID numbers, allowed for
receiving.
- [Repeater filter] – enter ranges (From which – To which) of repeater numbers allowed for receiving.
Settings in branch Reports:
Setting output parameters for the monitoring software or
transmission modules:
6.
Set output protocol:
6.1.
When using MonasMS monitoring software set the
[Output protocol] to the Monas3. Otherwise, select
Surgard or Ademco protocol.
6.2.
Uncheck [Repeater Mode].
6.3.
Set following required parameters: [Receiver Number],
[Line number], [System], [Account ID], [HB Period] and
[Baud Rate] for RS232.