![Trikdis GV15 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/trikdis/gv15/gv15_user-manual_1162624007.webp)
©1997-2015 TRIKDIS
7
www.trikdis.com
Controller GV15
Controller components
Light indication
Indicator
Status
Description
Network
Off
Controller is turned off or GV15 initiation in
progress
Blinking
Registration to GSM network in progress
Lighting for 5 sec.
+ N flashes
N - relative GSM signal level
3 flashes
–
minimum sufficient level (30%),
10 flashes
–
maximum (100%)
Data
Off
No operations
On
Data
processing
(receiving
a
call
or
receiving/sending
SMS/programming
in
progress)
Power
Off
Too low supply voltage or no power supply
Lighting
Normal power supply
Trouble
Off
Non troubles
Lighting for 5 sec.
+ N flashes:
1 flash
Insufficient supply voltage
2 flashes
No SIM card
3 flashes
PIN code error
4 flashes
Registration to GSM network within 60 seconds
failed
5 flashes
Operation mode setting error *
6 flashes
Threshold GSM signal level (~ 30%)**
7 flashes
Critical error in the parameters structure
8 flashes
Error in the user phone number list structure
Notes:
* - not a single administrator phone number is entered and the user list is prohibited.
** - use a portable GSM antenna with a cable and fit it to the exterior of the case if a controller is mounted into the
metal case of automatics.