Trikdis E10Tv2 Скачать руководство пользователя страница 8

 

 

 

 

 

©1997-2017 Trikdis  

8  

www.trikdis.com  

 

Ethernet communicator E10Tv2 

3.4

 

System settings 

Settings → General: 

 

Write an appropriate Account number (4 symbols hexadecimal number).  

 

Select Use security panel account ID checkbox if messages from the security control panel must contain 
its identification number. 

 

Test period: periodic test messages will be sent according to a time interval set in this section 

Settings → Ethernet settings 

 

Enter Internal MAC. 

 

When Use DHCP checkbox is selected, module registration in the network will be done automatically.  

o

 

If automatic registration is unsuccessful, enter Internal IP address, subnet Mask and Gateway address 
manually. E10Tv2 supports DNS service; 

Settings → Access  

 

Administrator code - allows full access to the configuration.

 

 

Installer  code  -  allows  access  to  the  configuration,  limited  by  administrator.  Administrator  can  allow 
installer to change: 

 

o

 

Account number; 

o

 

Reporting; 

o

 

Ethernet settings; 

o

 

Event summary. 

Figure 4. System setting window

 

Содержание E10Tv2

Страница 1: ...Ethernet communicator E10Tv2 USER MANUAL UAB TRIKDIS Draugyst s str 17 LT 51229 Kaunas LITHUANIA E mail info trikdis lt Webpage www trikdis lt...

Страница 2: ...PANEL 5 CONFIGURATION AND OPERATION 6 3 1 MAIN STEPS TO CONFIGURE COMMUNICATOR VIA USB CABLE 6 3 2 MAIN STEPS TO CONFIGURE COMMUNICATOR REMOTELY 6 3 3 TRIKDISCONFIG BASICS 7 3 3 1 Main action buttons...

Страница 3: ...ion to control panels via TLC terminal connection Communications Communication modes Ethernet Communicator transfers all messages from control panel in Contact ID codes Simultaneous event reporting to...

Страница 4: ...other household waste 1 2 Technical Parameters Parameter Description Power supply voltage DC 12 6 3 V Current consumption 120 mA stand by Up to 250 mA transmitting Ethernet connection IEEE802 3 10 Bas...

Страница 5: ...control panel Power displays power supply status and the functioning of the microprocessor Green flashing Power supply is sufficient Yellow flashing Power supply is not sufficient 11 5 V Installation...

Страница 6: ...onfig program to communicator 3 2 Main steps to configure communicator REMOTELY Make sure that the communicator is connected to supply source and is operating 1 Start TrikdisConfig software 2 At the f...

Страница 7: ...To read about communicator s functionality and how to configure specific parameters click Help F1 and from the program menu select the section This will open an appropriate chapter from the user manu...

Страница 8: ...is section Settings Ethernet settings Enter Internal MAC When Use DHCP checkbox is selected module registration in the network will be done automatically o If automatic registration is unsuccessful en...

Страница 9: ...ymbol hexadecimal number 3 6 Reporting Protegus service Protegus service allows users to remotely monitor and control the communicator Protegus service allows simultaneous transmission of data to the...

Страница 10: ...changed manually After an update all the previous communicator parameters will remain the same When writing firmware manually it can be changed to a newer or older version To update 1 Run TrikdisConf...

Страница 11: ...E10Tv2 can be controlled remotely using TrikdisConfig software To do so follow steps below 1 Open TrikdisConfig 2 At the field Remote access in the field Unique ID enter the MAC address MAC address i...

Страница 12: ...ivations refer to chapter 3 7 Event Summary NC Normally Closed NO Normally Open EOL End of line Performance test 1 After configuration and installation is complete perform a system test Activate an ev...

Отзывы: