3.4
System settings
Settings → General:
•
Write an appropriate Account number (4 symbols hexadecimal number).
•
Select Use security panel account ID checkbox if messages from the security control panel must contain
its identification number.
•
Test period: periodic test messages will be sent according to a time interval set in this section
Settings → Ethernet settings
•
Enter Internal MAC.
•
When Use DHCP checkbox is selected, module registration in the network will be done automatically.
o
If automatic registration is unsuccessful, enter Internal IP address, subnet Mask and Gateway address
manually. E10Tv2 supports DNS service;
Settings → Access
•
Administrator code - allows full access to the configuration.
•
Installer code - allows access to the configuration, limited by administrator. Administrator can allow
installer to change:
o
Account number;
o
Reporting;
o
Ethernet settings;
o
Event summary.
Figure 4. System setting window