Minipak

You will hear two beeps.

Note: Day entries must be 2 digits (start and end day).

Note: To program the relay to operate only one day a
week, enter the digit for that day twice (“6 6” means
Saturday only).

 6. Enter "# #" to exit Program Mode, otherwise,
continue programming by entering the desired
function code.

(N) Master Erase:

This procedure allows selective or complete deletion of
all data in the Minipak’s memory.  Also, it is possible to
reset the Minipak back to its factory defaults (presets).

Note:  Use caution when performing these steps.

1.Unit must be in Program Mode(see section A),

2. Enter " 

 

".

3. Enter "0" if you wish to erase all data and reset
unit back to factory defaults.

4. Enter "1" if you wish to erase all Entry Codes
only.

5. Enter "2" if you wish to erase all Resident Code/
telephone numbers only.

6. Enter "3" if you wish to reset the unit back to
factory defaults, leaving all other memory intact.

Upon completion of the full master erase sequence, you
will hear a long series of beeps.

Note: Master Erase time will vary greatly depending on
memory type, usage and capacity.

 7. Enter "# #" to exit Program Mode, otherwise,
continue programming by entering the desired
function code.

(L) Programming Primary Relay  on/off schedule:

This feature allows time clock control of Primary Relay.
You may set the relay to activate at a certain time of
day and deactivate at a later time of the same day.  Also,
you may set this daily on\off action to happen within a
certain part of the week; i.e. Tuesday through Friday.

Note:  (TIME Clock Option required) Military time
format (24 hour clock) is used in clock programming.

To program Primary Relay, do the following:

1. Unit must be in Program Mode (see section A).

2. Enter "#  4"

3. Enter Start Time  

(Use military format of

hours:minutes, i.e. “0600” , “1500”).  Entry must be
four digits.

4. Enter End Time  

(same four digit format as above).

5. Enter Start Day and End Day 

("1 thru 7" means

Monday through Sunday).  For example, entering 24
would set the clock for Tuesday through Thursday.

You will hear two beeps.

Note: Day entries must be 2 digits (start and end day).

Note: To program the relay to operate only one day a
week, enter the digit for that day twice (“6 6” means
Saturday only).

 6. Enter "# #" to exit Program Mode, otherwise,
continue programming by entering the desired
function code.

(M) (Requires Time Clock Option)

Programming Secondary  Relay on/off schedule:

This feature allows time clock control of optional
Secondary Relay. You may set the relay to activate at a
certain time of day and deactivate at a later time of the
same day.  Also, you may set this daily on\off action to
happen within a certain part of the week; i.e. Tuesday
through Friday.

Note: Military time format (24 hour clock) is used in
clock programming .

To program Secondary Relay, do the following:

1. Unit must be in Program Mode (see section A).

2. Enter "#  5"

3. Enter Start Time  

(Use military format of

hours:minutes, i.e. “0600” , “1500”).  Entry must be
four digits.

4. Enter End Time  

(same four digit format as above).

5. Enter start day and End Day 

("1 thru 7" means

Monday through Sunday).  For example, entering 24
would set the clock for Tuesday through Thursday.

PROGRAMMING, Continued

PROGRAMMING, Continued

PROGRAMMING, Continued

PROGRAMMING, Continued

PROGRAMMING, Continued

Содержание Minipak

Страница 1: ...Circle Corona CA 92880 800 842 7444 Info trigonelectronics com www TrigonElectronics com August 6 2008 INSTALLATION and OPERATION INSTRUCTIONS Universal SMT Version Multi Number Telephone Entry Syste...

Страница 2: ...Entry Codes 7 Changing the Program Code 7 Deleting Entry Codes 7 Entering Access Cards 8 Deleting Cards 8 Programming Site ID Code 8 Programming Tamper Code 8 Programming Optional Time of Day Clock 8...

Страница 3: ...ne numbers and up to 400 personal entry codes and is PBX compatible It is constructed for rugged outdoor use Its long lasting brushed finish stainless steel housing complements its thin design lines N...

Страница 4: ...und wire to the ground location on the terminal block This ground wire should go to a grounding rod or grounded metal conduit 5 Trigon recommends that an EMI filter Cornell Dubilier Model APF 1021 or...

Страница 5: ...ke Connections Voice Grade 24 to 48V 22AWG Shielded or Twisted up to 2400 Telephone Cable Telco Ground Ear Mouth Mic Spkr Out RTS In HOOK DS R COM PG Microphone Adjustm ent Speaker Volume 5 AMP Primar...

Страница 6: ...UP SYSTEM SETUP SYSTEM SETUP SYSTEM SETUP SYSTEM SETUP General Programming Information The Initial Setup for the Miniguard IID has been programmed at the factory These factory default settings may be...

Страница 7: ...for Adding Telephone Numbers and enter the new number in place of the old one The old number will be overwritten D Programming Entry Codes Entry Codes make it possible for the resident to enter a Code...

Страница 8: ...continue programming by entering the desired function code I Programming Site Identification Code In the case of multi unit installations the Site Identification Code makes it possible for the party r...

Страница 9: ...ME Clock Option required Military time format 24 hour clock is used in clock programming To program Primary Relay do the following 1 Unit must be in Program Mode see section A 2 Enter 4 3 Enter Start...

Страница 10: ...rding a new voice message O Recording a new voice message O Recording a new voice message To change the voice message on the voice chip follow these steps 1 Referring to Page 5 move jumpers W1 W3 and...

Страница 11: ...tenant answer Granting Visitor Entry Answer telephone and identify visitor You may choose from the following options fig 4 1 Enter 0 to activate Primary Relay and disconnect Note On rotary telephones...

Страница 12: ...ouch tone echo test Unit will echo any touch tone you send with your phone 2 Press to escape from this test 3 Enter 1 for memory test One tone good two tones bad 4 Enter 2 for touch tone sequence Unit...

Страница 13: ...KER 1 Phone wires running in same conduit as AC power 2 Unit not properly grounded 3 Defective microphone RESIDENT CANNOT HEAR VISITOR 1 Defective handset microphone 2 Too much background or street no...

Страница 14: ...lock MM DD YY hh mm d none installed 4 Verify Relay One Schedule hhmm hhmm d d not set 5 Verify Secondary relay schedule 6 Verify Tamper Code rrrr not set 7 Verify Program Code pppp 8 Verify Site ID C...

Страница 15: ...Programming Directly on keypad or remotely by DTMF tones Power 120VAC 12VAC 40VA Class 2 trans former included Relay Ratings Primary Relay 5 AMPS 30 VDC 250VAC 1 8 HP 120VAC Alarm Shunt Relay 250ma 1...

Страница 16: ...Page 16 Minipak...

Отзывы: