background image

Trident Emergency Products, 

LLC

2940 Turnpike Drive | Suite #9 | Hatboro, PA 19040 USA
215-293-0700 

Phone

215-293-0701 

Fax

[email protected] 

Email

TridentDirect.com

World Class 

Fire Industry 

Products

AirPrime™ is a trademark of 

Trident Emergency Products, LLC

Repair/Replacement Parts

#02.003.1e 

 06/25/2019

REF #

DESCRIPTION

PART #

1a

Solenoid Valve 12-Volt

30.003.2

1b

Solenoid Valve 24-Volt

30.003.3

2

Air Filter Replacement for 1/4" NPT Bore

21.002.0

3

Piston

11.001.0

4

Valve Stem

05.002.0

5

Seal Washer

04.004.0

6

3/4" Wye Strainer (Replacement Screen: 21.003.1)

21.003.0

7

Rebuild Kit (Seals, Mesh Filter, Spring Valve Plate, Fasteners)

27.003.3

8

Pressure Protection Valve (PPV)

30.053.0

9

Lift Gauge

14.006.0

10a

Rocker Switch 12-Volt and Label Assembly

27.003.5

10b

Rocker Switch 24-Volt and Label Assembly

27.003.6

11

Label Only: 

Rocker Switch

02.004.2

12

Pressure Switch and Connector

40.002.1

13a

Rocker Switch 12-Volt, Label, Mounting Plate, Lift Gauge Assembly

27.003.7

13b

Rocker Switch 24-Volt, Label, Mounting Plate, Lift Gauge Assembly

27.003.8

14

Label Only: 

Rocker Switch with Lift Gauge

02.004.4

REF #

DESCRIPTION

PART #

15a

Rocker Switch 12-Volt Replacement

40.001.2

15b

Rocker Switch 24-Volt Replacement

40.001.3

16

Wiring Harness for Auto AirPrime

41.001.0

17

Push Button, Label, and Mounting Plate Assembly

27.003.1

18

Label Only: 

Push Button

02.006.4

19

Push Button Replacement

30.005.3

20

Push Button, Label, Mounting Plate and Lift Gauge Assembly

30.005.4

21

Label Only: 

Push Button with Lift Gauge

02.006.10

22

Remote Priming Valve (RPV)

30.035.1

23

1/4" NPT Air Check Valve

30.012.0

24a

Remote Priming Valve with 12-Volt Solenoid

30.035.10

24b

Remote Priming Valve with 24-Volt Solenoid

30.035.11

25

Multi-Location Push-Button w/ Mounting Plate

27.003.9

26a

Label Only: 

Primer Front Intake

02.006.5

26b

Label Only: 

Primer Rear Intake

02.006.6

26c

Label Only: 

Primer Left Side

02.006.7

26d

Label Only: 

Primer Right Side

02.006.8

AirPrime Conversion Kits and Rebuild Kit

Conversion Kit:

 Single Location AirPrime System, Converts Manual to Automatic

27.014.0

Conversion Kit: 

Multi-Location AirPrime System, Converts Manual to Automatic

27.014.1

Conversion Kit: 

Manual AirPrime System, Converts Single (1) Location to Dual (2) Location

27.005.2

Conversion Kit: 

Automatic AirPrime System, Converts Single (1) Location to Dual (2) Location

27.005.3

Conversion Kit: 

Multi-Location AirPrime System, Adds Additional Locations Going From (2) Location to (3) Location. 

Or From (3) Location to (4) Location

27.005.1

Conversion Kit: 

Automatic AirPrime System, Adding a Lift Gauge to existing Automatic AirPrime. Requires .125" NPT Port. Contact Factory for Details

27.005.5

Conversion Kit: 

Manual AirPrime System, Adding a Lift Gauge to existing Manual AirPrime. Requires .125" NPT Port. Contact Factory for Details

27.005.4

Conversion Kit: 

Manual AirPrime, Converting to Auto with Lift Gauge. Requires .125" NPT Port. Contact Factory for Details

27.005.6

Rebuild Kit:

 Contains Seals, O-Rings, Spring Valve Plate, Domed Inlet Filter and Fasteners

27.003.3

26

6

7

8

9

12

15

16

19

22

24

25

1

5

4

6

2

10

a,b

11

13

a,b

14

17

18

20

21

Automatic

AirPrime Parts

Manual

AirPrime Parts

Multi-Location

AirPrime Parts

Air F

low

23

3

21.003.1

a,b

a,b,c,d

a,b

a,b

Содержание AirPrime Series

Страница 1: ...Prime Models Automatic Controls Manual Controls t Lift Gauge Option Standard Control q Lift Gauge Option u q Standard Control AIRPOWER SC 1901 Self Contained Priming System SC 1906 Self Contained Priming System AirPrime Pressure Regulator For use with high pressure SCBA cylinders ...

Страница 2: ...s for Manual to Automatic and for adding more locations are available Refer to Page 16 5 AirPrime is also available for small trucks without air brakes See Page 5 for additional information For more information on all available models please visit www TridentDirect com or www TridentAutoAirPrime com Contents Available Models 2 AirPrime Overview 2 AirPrime How Does It Work 3 Installer Responsibilit...

Страница 3: ...d fire ground operations and safety Auto Prime Move Switch to the upper position The Green LED light will illuminate The primer will activate when the OK TO PUMP light is ON and the Pump Pressure is below 20 PSIG The Auto Mode only operates when the fire pump is engaged AirPrime Primers can be used for both New and Retro Fit installations In Retro Fit scenarios AirPrime may be used to augment the ...

Страница 4: ...quired for all threaded pneumatic fittings NOTE Use sparingly while applying sealant to avoid blockage of the internal mesh air filter See Page 5 Figure 5 Remote Primer Mounting 1 An installer supplied primer bracket shall be installed to secure the primer within the pump enclosure The mounting height for all priming components must be ABOVE the highest priming point on suction side of fire pump o...

Страница 5: ... and must not be run near exhaust pipes Stay 6 150 mm away from any exhaust or hot components muffler or rotating shafts Use grommets to protect the tubing lines from contacting sharp edges at hole locations When the length of tubing required exceeds 20 feet 6 1 m a minimum size of 1 2 OD air brake tubing should be used Pressure Protection Valve PPV The Pressure Protection Valve 4 is not supplied ...

Страница 6: ...switch in AUTO PRIME mode 2 If drafting connect all suction hoses strainer and tighten accordingly Utilize wheel chocks In cab Apply parking brake Engage pump per manufacturers recommendations AirPrime will start priming automatically when the pump is engaged NOTE Never run a fire pump dry for more than 45 seconds 3 Pump Panel Verify that the green OK TO PUMP light is ON and then increase RPM When...

Страница 7: ... pump shift control circuit PTO or split shaft 1 5 feet long 5 m Red and Black wires to power supply 1 foot long wiring and 1 amp fuse by installer Plug in to AirPrime solenoid connection 5 feet of cable 1 8 m Plug in to fire pump discharge pressure switch 5 feet of cable 1 8 m See Figure 6 on Page 6 6 Connect a 1 4 OD 6 35 mm tubing line Not supplied from the push to connect fitting supplied on t...

Страница 8: ...erated simply by increasing the engine speed to a maximum of 1000 RPM and depressing the push button on the panel Hold the button down until the discharge pressure gauge begins to rise The primer will stop running when the push button is released The push button will operate the primer regardless of whether the fire pump is engaged or not 1 Depressing the Push To Prime button directs air to the pr...

Страница 9: ... push button control as shown in Photo 5 7 Gold labels are provided for LEFT RIGHT FRONT and REAR remote priming locations as shown in Photo 6 8 See Photos 3 and 4 to note that the cast in arrows on the RPVs and Check Valves are in the proper direction of flow Operating Instructions for Multi Location Automatic Priming System 1 See operating instructions for automatic priming system on Page 6 for ...

Страница 10: ...ubing Minimum 3 8 Tubing Minimum 3 8 Tubing Min 3 4 Tubing Minimum 3 8 Tubing Min Drawing Denotes Two 2 Additional Multi location Priming Points Check Valve Panel Switch Color Key Electric Lines Air Supply Lines Vacuum Priming Lines Multi Location Wiring Harness 3 4 Tubing Minimum See photo inset lower left corner Out Figure 16 Color Key 3 4 ID External Flex Line 3 4 ID External Flex Line 3 4 ID E...

Страница 11: ...ion Color Key 3 4 ID External Flex Line to Low Point Drain 1 2 ID Internal Flex Line 3 4 ID External Flex Lines 1 2 or 5 8 ID External Flex Line 1 2 ID Internal Flexible Tubing Priming Line Drain Valve 1 2 or 5 8 ID External Flexible Tubing 3 4 Weld Coupling 3 4 ID External Flex Tubing Merge All High Point Pickups At The Valve Location Higher Than The High Points Fittings In Kit From Outside Of Pi...

Страница 12: ...l AirPrime Remove air supply piping remove fine mesh filter clean or replace Part 21 002 0 b Automatic AirPrime Remove air supply piping remove air solenoid assembly remove fine mesh filter clean or replace Part 21 002 0 Slight air leak in discharge or intake valves in fire pump plumbing Hydrostatic test the plumbing system to NFPA 1901 standard with wet fire pump and closed valves 250 PSIG 17 2 B...

Страница 13: ...ed Master Intake Valves on suction intakes a Remove the MIV and cap intake b Install a cap on the discharge side of the relief valve c Cap the Storz or NH intake Check the AirPrime integral priming valve a The priming valve is not seating in the shut off position remove primer disassemble and check the priming valve spring seat and operation b The priming valve is stuck check for damaged O Ring or...

Страница 14: ... pumping test outlined in the NFPA standards 2 Engage the pump and increase the throttle to a maximum engine speed of 1000 RPM 3 Operate the AirPrime with the air system at over 100 PSIG 7 0 Bar pressure air tanks filled to capacity and at 1000 RPM engine speed For the Manual controlled primer release the push button when a discharge pressure over 20 PSIG 1 4 Bar is obtained For the Automatic AirP...

Страница 15: ...rty can result from improper selection or improper use of products described in this instruction manual Since TRIDENT has no control over the number and variety of applications for which its products may be purchased or the conditions under which they may be used TRIDENT liability on any claim whether in contract tort including negligence or otherwise for any loss or damage shall in no case exceed...

Страница 16: ...uge 02 006 10 22 Remote Priming Valve RPV 30 035 1 23 1 4 NPT Air Check Valve 30 012 0 24a Remote Priming Valve with 12 Volt Solenoid 30 035 10 24b Remote Priming Valve with 24 Volt Solenoid 30 035 11 25 Multi Location Push Button w Mounting Plate 27 003 9 26a Label Only Primer Front Intake 02 006 5 26b Label Only Primer Rear Intake 02 006 6 26c Label Only Primer Left Side 02 006 7 26d Label Only ...

Отзывы: