background image

11

Ignition HT Spark
Spark Generator

Ispra Control's BF 50046 - 240V   0.6 YA   T 120

Spark Gap

Fixed

Rear Left Burner (semi rapid)
Heat Input

1.9 kW (6483 BTU/HR)

Front Left Burner (rapid)
Heat Input         2.9 kW Natural Gas (9895 BTU/HR)
                                   2.7 kW L.P.G. (9212 BTU/HR)

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

510 mm.

Thickness: 40 mm.
Height:

88 mm.

Weight:

11 Kg.

SUPPLY CONNECTIONS

Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:
240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

This appliance complies with the EEC Directive No 89/336, concerning suppression of radio electrical
interference.

Burner

Dia. Tap By-pass

Tap colour

1/100 mm

Auxiliary

28

Red/Red

Semi-rapid

32

Blue/Blue

Rapid

40

Black/Black

Aeration adjustement none

INSTRUCTIONS FOR THE INSTALLER -  TECHNICAL DATA

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

 NOMINAL THERMAL
 POWER                        kW

2.9

0.65

1.9

0.45

1.0

0.33

 NOMINAL FLOW
 RATE                         m

3

/h

0.276

0.062

0.181

0.043

0.095

0.031

 NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

 NOMINAL THERMAL
 POWER                        kW

2.7

0.65

1.9

0.45

1.0

0.33

 NOMINAL FLOW
 RATE                            g/h

195

46.8

137

32.4

72

23.8

 NOZZLE REFERENCE

86

40

71

32

50

28

NATURAL GAS

20 mbar

TYPE OF

GAS

CHARACTERISTICS

LPG GAS

28-30/37 mbar

1/100 mm

1/100 mm

VALUE = 49.92 MJ/Kg

VALUE = 37.78 MJ/m

3

Ws - 50.7 MJ/ m

3

Rear Right Burner (semi rapid)
Heat Input

1.9 kW (6483 BTU/HR)

Front Right Burner (auxiliary)
Heat Input

1.0 kW (3412 BTU/HR)

Содержание HG 250

Страница 1: ...2 Better Products Better Value MODEL NOS GAS HOB INSTRUCTION BOOKLET INSTALLATION AND SERVICING INSTRUCTIONS HG 250 35668 9401 GB ...

Страница 2: ... use and retain their heat for a long period of time after use You must therefore take great care when using the appliance Children should be supervised at all times and should not be allowed to touch the hot surface or be in the vicinity when in use or until the appliance has cooled after use Children also can injure themselves by pulling pans or pots off the hob The cooking zones heat up quickly...

Страница 3: ...y Requirements Page 14 Electrical Connection Page 15 Wiring Diagram Page 16 Fault Finding Page 17 Commissioning Page 19 Servicing Page 20 Convert from natural gas to LPG Page 20 These instructions are only for the country stated by the symbol printed on the front cover of this instruction book CLASS APPLIANCE 3 APPLIANCE CATEGORY II2H3 APPLIANCE GAS SUPPLY Natural gas G20 20mbar MANUFACTURER ELECT...

Страница 4: ...ent of a breakdown INSTRUCTIONS FOR THE USER This appliance meets the requirements laid down in EEC directive No 89 336 relating to the suppression of radio and TV interferences WHEN THE HOB IS FIRST INSTALLED Once the hob has been installed it is important to remove any protective materials which were put on in the factory DESCRIPTION OF THE APPLIANCE 1 Hob Top 2 Rapid Burner 3 Semirapid Burners ...

Страница 5: ...nd pans with a flat bottom fitting the size of the burner used see table so that flame will not spread beyond the bottom of the vessel It is also advisable as soon as a liquid starts boiling to turn down the flame so that it will barely keep the liquid simmering IMPORTANT Be very careful when frying food in hot oil or fat as the overheated splashes could easily ignite IMPORTANT If the control knob...

Страница 6: ...n booking a service call we will need to know the model number and date of purchase together with your name address with postcode service areas are defined by the postcode telephone number and what appears to be wrong Keep the receipt with this booklet as proof of purchase CUSTOMER RELATIONS DEPARTMENT For general enquiries concerning your Tricity Bendix appliance or further information on Cookers...

Страница 7: ...1745 591616 North Wales LN1 2 4 6 LN3 Subcodes 4 5 LN8 10 01522 514603 Lincoln LN3 Subcode 6 only LN7 11 13 01472 267978 S Humberside LS 0113 2608511 Leeds LU 0181 9659699 Canvey M 0161 4777758 Manchester ME 01732 357722 Tonbridge MK 0181 9659699 Canvey ML 0141 6474381 Glasgow N 0181 4433464 Canvey NE 0191 4932025 Northern NG1 22 25 0113 2608511 Leeds NG23 24 31 34 01522 514603 Lincoln NN 01203 35...

Страница 8: ...Service Unit 7D Pool Industrial Estate Wilson Way Redruth Cornwall TR15 3QW ROTHSAY Tricity Bendix Service Force D McGlashan Walker Eng Glenmhor Upper Serpentine Rothsay Strathclyde PA20 SHETLAND Tricity Bendix Service Force George Robertson 3 4 Carlton Place Lerwick Shetland ZE1 0ED SHETLAND Tricity Bendix Service Force Tait Electronic Systems Ltd Holmsgarth Road Lerwick Shetland ZE1 0PW SHETLAND...

Страница 9: ...ectrolux Group Service Centre Home visits are made between 9 00am and 5 00pm Monday to Friday Visit may be available outside these hours in which case a premium will be charged Any appliance or defective part replaced shall become our property EXCLUSIONS This guarantee does not cover Damage or calls resulting from transportation improper use or neglect the replacement of any light bulbs or removab...

Страница 10: ...pass Tap colour 1 100 mm Auxiliary 28 Red Red Semi rapid 32 Blue Blue Rapid 40 Black Black Aeration adjustement none INSTRUCTIONS FOR THE INSTALLER TECHNICAL DATA CUT OUT DIMENSIONS Width 550 mm Depth 470 mm BURNER RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN NOMINAL THERMAL POWER kW 2 9 0 65 1 9 0 45 1 0 0 33 NOMINAL FLOW RATE m3 h 0 276 0 062 0 181 0 043 0 095 0...

Страница 11: ...sher C Adjustable join It is important to install the elbow correctly with the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas Fig 2 FO 0264 FO 0814 550 470 580 510 55 min FO 2109 Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for c...

Страница 12: ... sealing gasket all around the glass top edge as shown in Fig 3 3 Fit the hob in the cut out and push it down until the glass top and the working top come in touch as shown in Fig 4 ON OFF SWITCH FLEX OUTLET ON OFF SWITCH FLEX OUTLET FO 0763 FO 0764 Fig 3 It is also recommended to carry out the electrical connection to the hob as shown in illustrations A and B A Fig 4 FO 2108 FO 2107 30 20 min 60 ...

Страница 13: ...5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements LOCATION The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom or shower room Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a sid...

Страница 14: ...e plug the colours of the wires in the flexible supply cord may not correspond with the markings identifying the terminals in the alternative plug In this case follow the procedure below Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug whic...

Страница 15: ...16 WIRING DIAGRAM 1 TAPS IGNITOR SWITCHES 2 IGNITOR UNIT 1 2 L N 0 220 240 1 2 3 4 ...

Страница 16: ...ould it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal evidence of burning around the fault START Isol...

Страница 17: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Страница 18: ...et to MIN Remove the control knob insert a thin bladed screwdriver down the centre of the gas tap control shaft and turn the adjustment screw until the flame is steady and does not extinguish when the knob is turned from MIN to MAX Repeat this procedure for all burners Pressure Testing Remove left hand pan support and front left burner cap and crown Fit manometer tube over the injector Turn on the...

Страница 19: ...on switches connector 3 With the aid of a pair of thin nose pliers pull the spring clip sidewards off of the underside of the ignitor 4 Reassemble in reverse order and check with wiring diagram for correct reconnection F Remove Taps Ignition Switches Isolate Electric Supply 1 Follow the procedures in Section A 2 Disconnect the switches connector from the ignitor unit and remove the supply cables p...

Страница 20: ...250 PART NO 35668 _____ Better Products Better Value TRICITY BENDIX 99 OAKLEY ROAD LUTON BEDFORDSHIRE LU4 9QQ A Division od Emaco Limited Registered in England No 176547 Registered Office 101 Oakley Road Luton LU4 9RJ ...

Отзывы: