Service personel must be accomodated with clear access to the plant.
•
If others size the plant, Tricel will supply to these specifications. In this case, the
responsibility lies with others in relation to the maximum flow/litres per day, the plant
capacity and retention times. Similarly, if Tricel size the plant and a greater load is then
placed on the plant by the addition of extra houses, bedrooms, schools, crèches, etc. or by
other means, Tricel is not responsible for the plant overloading or the quality of effluent as
the retention times may be compromised.
•
Should the plant be used intermittently or if extended periods of non-use are expected,
it is recommended that the plant remains on and in operation. The contents of the
plant should not be allowed to turn septic due to non-use.
•
The tank is not suitable for vehicular traffic. Tricel also recommends fencing off the area to
prevent livestock herds from accessing the p l an n t. Where possible, unnecessary human
traffic around the plant should be avoided.
•
The Tricel Novo is only suitable for human faeces. No animal faeces must enter the
plant.
10
Troubleshooting
Properly installed, operated and maintained plants will give many years of trouble free service. All plants
are fitted with an alarm, which will alert to irregularities in the plant. If a blower or pump stops working
a buzzer will sound to indicate there is a problem with the plant. The buzzer can be muted until the
problem is fixed. Once fixed, the alarm will reset automatically and the mute switch must be turned off.
All electrical work shall be carried out by a certified electrician.
10.1
Plant operation
Symptom
Possible causes
Solution
Blower/Pump will not
start or run
Fuse blew (if applicable).
Replace with a fuse of suitable size.
Tripped breaker.
Reset breaker.
Low line voltage and wet
electrics.
An electrician should check the power supply to
the plant.
Defective blower/pump.
Blower/pump must be checked by a qualified
person.
Thermal overload
protection triggered by
high ambient temperature.
Allow the blower time to cool. The blower will
automatically restart when cooled sufficiently.
Содержание Novo UK10
Страница 1: ...0 106 Rev 11 Dec 2017 Tricel Novo UK6 50 Wastewater Treatment Plants Engineering a green future...
Страница 4: ...3...
Страница 5: ...4...
Страница 10: ...9...
Страница 11: ...10...
Страница 26: ...25 5 11 1 Electrical Diagrams 5 11 1 1 Tricel Novo Gravity Outlet UK6 UK8 UK10 UK12 Control Panel No 209102...
Страница 27: ...26 UK18 UK24 Control Panel No 209116...
Страница 28: ...27 UK30 UK36 UK42 UK50 Control Panel No 209111...
Страница 29: ...28 5 11 1 2 Tricel Novo Pumped Outlet UK6 UK8 UK10 UK12 UK18 UK24 Control Panel No 209101...
Страница 30: ...29 UK30 UK36 UK42 UK50 Control Panel No 209112...
Страница 42: ...41 12 Terms conditions Subject to our standard terms and conditions which are available on request...
Страница 43: ...42...