TriboServ 214574 Скачать руководство пользователя страница 11

FlexxPump4 BXXX-EXT

Supplementary Sheet

Revision: 1

11

EN

-

4. Mount the upper housing from the pump 

unit of the FP4 BXXX-EXT.

 Place the disassembled upper part on the 

FP4 BXXX-EXT and press it onto the pump 

unit.

 Fasten the upper housing to the pump 

unit by turning the retaining ring clockwise.

 

The retaining ring must click into place 

when turned and must be completely tigh-

tened.

 Carry out the work according to the above description.

 If an error was displayed in the LCD before the cartridge was changed, the indicator 

now disappears, as does the red LED which flashes every 5 seconds. A separate ack

-

nowledgement is not required. The green LED flashes briefly every 60 seconds.

 After completion of this work, the FP4 B automatically returns to the last active mode 

(ON or OFF) before the work.

 If the empty cartridge level (error E1) has been reached during a dispensing cycle, 

the cycle will be automatically interrupted and automatically continued after completion 

of the work.

4. Mounting the lubricant cartridge

 Place the filled lubricant cartridge on 

the FP4 BXXX-EXT with the label facing 

forwards.

 Turn the lubricant cartridge clockwise onto 

the FP4 BXXX-EXT.

 

The end position is reached after two 

full rotations when the label of the lubricant 

cartridge is aligned with the front of the FP4 

BXXX-EXT.

Содержание 214574

Страница 1: ...ary sheet s in the original user manual remain valid without exception Further supplementary sheets to the original instruction manual are valid in addition to this supplementary sheet This document i...

Страница 2: ...e LCD on the front panel displays the various operating states further information empty cartridge error can be read The present FlexxPump4 as battery version has no electrical interface The supplied...

Страница 3: ...tment for battery pack or battery holder 8 Nameplate with designation CE mark and serial number 9 Through hole for assembly on both sides Fig 1 Overview FP4 BXXX EXT The FP4 BXXX EXT is available in s...

Страница 4: ...EXT Supplementary Sheet Revision 1 04 EN 3 4 Technical data Electrics Battery sizes alkaline or lithium TriboServ standard battery pack 6V 4x R6 with 1 5V or 4x R14 with 1 5V primary cells or recharg...

Страница 5: ...ondition as delivered The FP4 BXXX EXT is delivered in a card board box Depending on the version orde red additional accessories such as a battery pack or lubricant cartridge are included 2 Mechanical...

Страница 6: ...let Pay attention to cleanliness when performing the work Be sure to avoid dirt liquids and foreign objects from entering the cartridge 3 Remove the housing from the power unit of the FP4 BXXX EXT Tur...

Страница 7: ...osition is reached after two full rotations when the label of the lubricant cartridge is aligned with the front of the FP4 BXXX EXT 5 Mount the upper housing from the pump unit of the FP4 BXXX EXT Pla...

Страница 8: ...attery packs Connect the new battery to the battery cable via the reverse polarity protected plug or insert new batteries into the matching battery holder and connect it to the reverse polarity protec...

Страница 9: ...se original lubricant cartridges with lubricant approved by the manufacturer Observe the maximum storability of the lubricant filled in car tridges NOTICE It is not possible to refill empty or opened...

Страница 10: ...ricant cartridge Losen the retaining ring at the marked positions 2 Remove the empty cartridge Turn the lubricant cartridge counterclock wise from the FP4 B and dispose of it Pay attention to cleanlin...

Страница 11: ...LED which flashes every 5 seconds A separate ack nowledgement is not required The green LED flashes briefly every 60 seconds After completion of this work the FP4 B automatically returns to the last...

Страница 12: ...ment Turn the four screws counterclockwise Once the screws are loosened the cover can be removed Remove the cover from the battery com partment Store the cover next to you 2 Remove empty battery pack...

Страница 13: ...e plug does not protrude from the battery compartment and become trapped when the cover is screwed on Carry out the work according to the above description If an error was displayed in the LCD before...

Страница 14: ...115 10 5 1 72 kg Alle Schlauchanschlussteile f r Schlauch 6mm All tube connection parts for tube 6mm Benennung Name Art Nr Item No Farbe Colors Schmierstoff Lubricant FlexxPump4 B412 EXT 214580 gr n g...

Отзывы: