revision: 0
FlexxPump4 DXXX-OIL
Supplementary Sheet
05
EN-
6.2 Assembly
2. Remove the housing from the power unit
of the FP4 DXXX-OIL.
Separate the housing from the power unit
by turning the retaining ring counterclock-
wise.
Make sure that no dirt, water or foreign
bodies enters the lubricant inlet.
Alternatively, you can remove the acti-
vation and programming key on the upper
housing of the FP4 DXXX-OIL to expose
the oil reservoir. Turn the action pin to the
OPEN position and pull it off.
1. Condition as delivered
The FP4 DXXX-OIL is delivered in a card-
board box.
Depending on the version ordered, further
accessories such as a lubricant cartridge or
additional tube connection parts are inclu-
ded.
3. Filling the oil cartridge
Fill the cartridge with oil until the mark
"max. level" on the oil cartridge is reached
Pay attention to cleanliness when
carrying out the work. It is imperative that
dirt and foreign bodies do not enter the
cartridge.