- 4 -

 

•  To ensure electromagnetic compatibility, make sure all connections are 

tight and that the covers are screwed on securely.

 

• No liability is accepted for damage caused by faulty connections or 

inappropriate handling of the device.

 

Electronic devices should never be disposed of in the household rubbish. In 
accordance with directive 2002/96/EC of the European Parliament and 
the European Council from January 27, 2003 which addresses old elec-
tronic and electrical devices, such devices must be disposed of at a desig-
nated collection facility. At the end of its service life, please take your 
device to one of these public collection facilities for proper disposal.

2 General 

information

2.1  Meaning of the symbols used

  Important note

  Danger by electrical shock

2.2  Scope of delivery

1  CSE 3319 head-end station (without cassettes), 
  power supply and control unit included
4  prestole nuts M 6 
4  fixing screws M 6 x 16 mm with plastic washers
1  CD (assembly instructions)

2.3 Available accessories

For cassettes and accessories see website “

http://www.triax.com

”.

Содержание CSE 3319

Страница 1: ...TRIAX your ultimate connection A A CLASS CLASS KLASSE KLASSE Assembly Instructions Art No 325102 GB CSE 3319 Head End Station...

Страница 2: ...used 4 2 2 Scope of delivery 4 2 3 Available accessories 4 2 4 Technical data 5 2 5 Description 6 3 Overview 7 4 Installing the head end station 9 4 1 EMC regulations 9 4 2 Installing cassettes 9 4 3...

Страница 3: ...ible ambient temperature range 10 C and 50 C can be main tained even during fluctuations in climatic conditions Ensure that the head end station is adequately ventilated Do not cover the ventilation o...

Страница 4: ...dresses old elec tronic and electrical devices such devices must be disposed of at a desig nated collection facility At the end of its service life please take your device to one of these public colle...

Страница 5: ...splitter Output frequency range of the RF collector 48 MHz 865 MHz Output level of the RF collector depending on the cassette fitted typ 80 dB V Output attenuation of the RF collector typ 18 dB Output...

Страница 6: ...tes are connected to the outputs of the input splitters The input splitters can be operated from a remote voltage supply that is the LNBs can be supplied with an operating voltage of 18 V and a curren...

Страница 7: ...ts 2 inputs E 9 outputs A per input 6 Two spare screws for the fixation of the cassettes 7 Type plate 8 Power supply connector accessible from the bottom 9 Opening for a ground terminal make the groun...

Страница 8: ...via one control unit only Control unit with display behind it the power supply unit The control unit The buttons on the control unit MULTI The function is dependent on the cassettes used MODE To next...

Страница 9: ...s necessary to connect the lines leading in and out of the 19 cabinet e g Cinch HF using standard cable terminals 4 2 Installing cassettes Before installing or replacing a cassette or the power supply...

Страница 10: ...material supplied 4 Prestole nuts M 6 4 fixing screws M 6 x 16 mm with plastic washers Precondition The rack system is completely assembled the support elements for placing the 19 unit are already ins...

Страница 11: ...tation into the rack system then fix it with the enclosed screws see Fig 6 Before putting the rack system into operation ground it according to the regulations DIN EN 50083 1 VDE 0855 Part 1 Fig 5 BU1...

Страница 12: ...ower supply plug 4 Set up the cassettes according to the instructions given in their user manuals 4 4 Power supply The power supply unit of the head end station is especially magnetically shielded Whe...

Страница 13: ...ified A circular aeration for example by means of ventilators is to be ensured inside the rack system In addition it is necessary to permanently control by means of thermo ele ments the ambient and op...

Страница 14: ...24V 0 1A 18V 0 3A 1 2 3 4 5 6 7 8 BU102 BU103 BU104 BU106 BU107 BU108 BU109 BU105 C107 L104 C107 L104 12V 1A 18V 0 3A 24V 0 1A 18V 0 3A 1 2 3 4 5 6 7 8 BU102 BU103 BU104 BU106 BU107 BU108 BU109 BU105...

Страница 15: ...display is automatically switched off or the software version of the control unit is displayed Note If desired the software version of the control unit can also manually be dis played in the following...

Страница 16: ...Alterations reserved Technical data E O E 18052009...